Start and stop the dehumidifier by
pressing the ON/OFF button.
When the compressor is working, the
compressor light is illuminated.
Set desired humidity
Press the UP and DOWN arrows
to choose desired humidity level
between 30% and 90%. The dehu-
midifier will shut off when desired
humidity level is reached. Set value
is shown in the display for a couple of
seconds. After, the display returns to
showing the ambient humidity level.
Press the DOWN arrow until the dis-
play shows CO to have the dehumidi-
fier running continuously.
When ambient humidity level is below
35%, the display shows LO. When
ambient humidity level is above 95%,
the display shows HI.
NOTE: when desired humidity level
is reached, the fan will continue to
work for a couple of minutes before
shutting off.
Set timer for automatic shut off
Press the timer button repeatedly to
active the timer for automatic shut off
between 1 and 24 hours. When acti-
vated, the timer light illuminates. Set
value is shown in the display for a
couple of seconds. After, the display
returns to showing the ambient humi-
dity level. Press the timer button until
the display shows 0 and the timer
light shuts off to deactivate. When
shut off due to the timer, you need to
press the power button to restart the
unit.
4.Water drainage
When the water reservoir is full, the
dehumidifier is shut off automatically.
Once the water reservoir is emptied
the unit will automaticallt restart.
1. Disconnect the dehumidifier from
the power source.
2. Empty the water reservoir.
3. Put the empty water reservoir back
and check that the float moves
freely.
English
4. Connect the dehumidifier to the
power source.
Direct water drainage
Connect a water hose (10 mm) to the
pipe on the back of the dehumidifier.
Lead the other end to a drain. Make
sure that the water can be drained
downwards.
5. The air filter
The air filter prevents dust and dirt
from entering the machine, prolong-
ing its life expectancy. It is important
the filter is cleaned regularly.
Filter cleaning:
1. Remove the filter.
2. Wash it with warm water and a
mild cleansing agent. Alternatively
the filter may be vacuum cleaned.
3. Let the filter dry and put it back.
It is very important that the
filter is cleaned regularly;
otherwise the dehumidifier
might lose capacity and even
be seriously damaged.
6. Maintenance
- Clean the unit with a soft moist
cloth. Do not use solvents or strong
cleaners as this might damage the
surface of the unit.
- The cooling coils are best cleaned
with a rag and warm water.
7. Service
If the dehumidifier requires servicing,
you must first contact your local retai-
ler. Proof of purchase is required for
all warranty claims.
5
8. Warranties
2 years product warranty. Please
note that the warranty is only valid
upon the production of the receipt.
This machine complies with EEC
directives 76/889 + 82/499
The unit is set to work between
+5ºC and + 35ºC.
If the temperature goes outside
this range the unit might not
work properly.
9. Hints
Sometimes it may be useful to use
a frost guard or heater fan to make
sure that the temperature does not
fall below +10˚C. Even if the M10
works down to temperatures as low
as +5°C, its capacity will increase
at higher temperatures as warm air
carries more water.
For maximum dehumidifying power
in a room, it is recommended that
the air supply from outside and from
adjoining rooms is minimized – close
doors and ventilators.
Expect higher dehumidification
capacity during Autumn / Summer
because the outside air is warmer
and more humid.
To achieve a safe and reliable pro-
tection against mould and moisture
damage, keep the relative humidity
between 50% and 60%.