7. CHANGING FOCUS RING AND LEMO CONNECTOR
Another unit system of focus ring (meter or feet, option) is available.
The pre-installed focus ring can be replaced with the optional focus ring.
7.1 Changing Focus Ring
a. Remove the four LEMO Connector installation screws ① .
b. Remove the LEMO Connector ② from the Lens main body.
Note . When you remove the LEMO Connector, be sure not to touch the internal printed circuit board
and switches. Otherwise, it may cause trouble, such as a communication failure. If the setting of a
switch is accidentally changed, contact the service center of our company.
c. Turn the Focus Ring ⑫ and align the ∞ (infinity) mark of the Focus Ring with Index Line ⑱ .
d. Remove the four Focus Ring installation screws ⑤ .
e. Slide the Focus Ring ⑫ toward the mount to remove it.
f.
Attach a new Focus Ring ⑫ (option) using the four screws (5) that were removed in step c.
Note . When you attach a new Focus Ring ⑫ , carefully align the Focus Ring and Lens positions so that
the ∞ (infinity) mark of the Focus Ring is aligned with Index Line ⑱ of the Lens main body.
g. Attach the LEMO Connector using the four LEMO Connector installation screws ① that were removed in
step a.
Note . After you remove the LEMO Connector installation screws ① and Focus Ring installation screws
⑤ , keep them in a safe place because they are required to attach the LEMO Connector and Focus
Ring. If the screws are lost, use the spare screws supplied with this product.
⑤
⑤
⑤
⑫
∞ (infinity) Mark
Index line ⑱
- -
①
②
①
⑤