FR
SERVICE D'ECS
INSUFFISANT
NON
OUVRIR LA VANNE
NON
NETTOYER LE FILTRE
LE DEBIT D'ECS
SI
SERA SUFFISANT
LORSQUE LA PRESSION DU
RESEAU REVIENDRA
FR
PERTE D'EAU DE
LA CHAUDIERE
REPERER LA FUITE,
SI C'EST NECESSAIRE
FERMER LE ROBINET
DE REMPLISSAGE ET
CONTACTER LE SAV
FR
BRUIT DANS LES RADIATEURS
42
LA TEMPERATURE
NON
PEU DE DEBIT?
DE L'EAU EST
BASSE?
OUI
OUI
VANNE
D'ARRET
Y-A-T-IL UN PREPARATEUR?
OUVERTE
OUI
NON
LE FILTRE
DIMINUER
DE LA VANNE
MELANGEUSE EST
LE DEBIT D'ECS
PROPRE?
OUI
LA PRESSION
NON
DU RESEAU A
APPELER LE SAV
VARIE?
PRESSION DE
OUI
LA CHAUDIERE
NON
CORRECTE?
(0,8-1,2 BAR)
NON
ARRETER LA CHAUDIERE,
FERMER LE ROBINET
DE REMPLISSAGE
ET CONTACTER LE SAV
RETABLIR LA PRESSION
LORSQUE LA CHAUDIERE EST FROIDE
NON
EN UTILISANT LE ROBINET DE
REMPLISSAGE ET VERIFIER
EN MEME TEMPS LA PRESSION
POSITIONNER
OUI
CORRECTEMENT
LE SELECTEUR
D'ECS
PRESSION DE
ROBINET DE
OUI
LA CHAUDIERE
REMPLISSAGE
SUPERIEURE A
DE LA CHAUDIERE
3 BAR?
FERME?
NON
FERMER LE
ROBINET DE REMPLISSAGE
DE LA CHAUDIERE
PRESSION DE
LA CHAUDIERE
OUI
LES RADIATEURS
CORRECTE?
SONT PURGES?
(0,8-1,2 BAR)
OUI
CONTACTER
L'INSTALLATEUR
ODEUR DE GAZ
LA FUITE
SE TROUVE
DANS LA
CHAUDIERE
NON
FERMER LA VANNE
GENERALE DU COMPTEUR
VENTILER LE LOCAL
ET APPELER LE SAV
FERMER LA VANNE D'ENTREE
GAZ DE LA CHAUDIERE
VENTILER LE LOCAL
ET APPELER LE SAV
REDUIRE LA PRESSION
OUI
SUR LA CHAUDIERE EN PURGANT
UN RADIATEUR ET
RETABLIR LA PRESSION
SI LE PHENOMENE
PERSISTE CONTACTER
LE SAV
PURGER LES RADIATEURS
NON
LORSQUE L'INSTALLATION EST
REMPLIE ET RETABLIR LA PRESSION
LORSQUE LA CHAUDIERE EST FROIDE
ALUFELL 30 SCT
ALUFELL 30 MT
OUI