10. Connection of the external
probe
The boiler is prearranged for connection of an external probe (supplied
as accessory).
For the connection, refer to the fi gure below and the instructions supplied
with the probe.
BOILER
CHAUDIERE
Fig. 38
When the external probe is connected, the heating circuit temperature
control device regulates the dispersal coeffi cient Kt.
The fi gures below show the relation between knob position and curves.
Intermediate curves may also be set.
Fig. 39
IMPORTANT: the TM delivery temperature value depends on the po si tion
of the jumper or the switch T.RISC. (see section on page 27). The
maximum possible temperature setting is 85 or 45°C.
EXTERNAL PROBE CONNECTION
CONNEXION SONDE EXTÉRIEURE
10. Connexion de la sonde
extérieure
La chaudière est prédisposée pour la connexion d'une sonde extérieure
(fournie comme accessoire).
Pour la connexion, voir la fi gure ci-dessous et lire la notice fournie avec
la sonde.
PANEL
PANNEAU
BOARD
CARTE
Lorsque la sonde extérieure est utilisée, le dispositif de contrôle de la tem-
pérature du circuit de chauffage régule le coeffi cient de dispersion Kt.
Les fi gures ci-dessous montrent la relation entre la position du bouton de
réglage et les courbes.
Il est également possible de défi nir des courbes intermédiaires.
TM = Range delivery temperatures - Plage des températures de refoulement
Te =external temperature - température externe
IMPORTANT : la valeur de la température TM dépend de la position du
cavalier ou du commutateur T.RISC. (voir page 27)
La température maximum de réglage est de 85 ou 45 °C.