INSTALLATION

Installing a Remote Control Enclosure

Remote control enclosures must be mounted on the front of
the unit to ensure the controls correspond with the correct wells
(the front of the unit is the side the conduit enters under the
unit). Remote control enclosures cannot be rewired and must
be installed in the proper location.
WARNING
ELECTRIC SHOCK HAZARD:
• Remote control enclosure must be mounted on vertical
wall and installed in vertical position. Mounting remote
control enclosure in horizontal position may result in
collection of liquids and lead to electric shock.
• Operating voltage of remote control enclosure water
valve exceeds 50 V (extra low voltage). Enclosure is
marked with the following hazard identification
symbol:
Model and Enclosure
HWBI-1 and HWBI43-1
Control w/Auto-Fill
Control w/o Auto-Fill
HWBI-2 and HWBI43-2
Control w/Auto-Fill
Control w/o Auto-Fill
HWBI-3 and HWBI43-3
Control w/ Auto-Fill
Control w/o Auto-Fill
HWBI-4 and HWBI43-4
Left Control w/ Auto-Fill
Left Control w/o Auto-Fill
Right Control
Control Enclosure w/ Auto-Fill *
Control Enclosure w/o Auto-Fill *
HWBI-5 and HWBI43-5
Left Control w/ Auto-Fill
Left Control w/o Auto-Fill
Right Control
Control Enclosure w/ Auto-Fill *
Control Enclosure w/o Auto-Fill *
HWBI-6 and HWBI43-6
Left Control w/ Auto-Fill
Left Control w/o Auto-Fill
Right Control
Control Enclosure w/ Auto-Fill *
Control Enclosure w/o Auto-Fill *
* HWBI-4, HWBI-5, and HWBI-6 units with all controls in a single control enclosure — required for Canadian units.
A
B
C

Control Enclosure Cutout Dimensions

Opening Dimensions
(A)
10-1/8" (257 mm)
5-3/4" (146 mm)
12-3/8" (314 mm)
8" (203 mm)
14-5/8" (371 mm)
10-1/4" (260 mm)
12-3/8" (314 mm)
8" (203 mm)
8" (203 mm)
16-7/8" (429 mm)
12-1/2" (318 mm)
12-3/8" (314 mm)
8" (203 mm)
10-1/4" (260 mm)
19-1/8" (486 mm)
14-3/4" (375 mm)
14-5/8" (371 mm)
10-1/4" (260 mm)
10-1/4" (260 mm)
21-3/8" (543 mm)
17" (432 mm)
D
Front View –
Control Enclosure
Control Enclosure Cutout Dimensions
NOTE: A qualified electrician should connect the unit(s) to a
power source. A qualified plumber should connect the
water supply and drain(s).
NOTE: Refer to the "Side Mounted Auto-Fill" or "Bottom
Mounted Auto-Fill" procedure in the OPTIONS AND
ACCESSORIES section before installing a Remote
Control Enclosure.
1. Cut and drill the appropriate holes in the mounting surface.
Refer to the "Control Enclosure Cutout Dimensions" chart
below for the cutout dimensions for each control enclosure.
• The cutout depth required for all control enclosures is
5" (127 mm).
• Make sure to have enough space inside the cutout if
installing with conduit on the side of the control enclosure.
• For units with two control enclosures: If the unit is
equipped with Auto-Fill, each enclosure cutout size will
be different (see chart below).
(B)
4-3/4" (121 mm)
10-7/16" (265 mm)
4-3/4" (121 mm)
6-1/16" (154 mm)
4-3/4" (121 mm)
12-11/16" (322 mm)
4-3/4" (121 mm)
8-5/16" (211 mm)
4-3/4" (121 mm)
14-15/16" (379 mm)
4-3/4" (121 mm)
10-9/16" (268 mm)
4-3/4" (121 mm)
12-11/16" (322 mm)
4-3/4" (121 mm)
8-5/16" (211 mm)
4-3/4" (121 mm)
8-5/16" (211 mm)
4-3/4" (121 mm)
17-3/16" (437 mm)
4-3/4" (121 mm)
12-13/16 (325 mm)
4-3/4" (121 mm)
12-11/16" (322 mm)
4-3/4" (121 mm)
8-5/16" (211 mm)
4-3/4" (121 mm)
10-9/16" (268 mm)
4-3/4" (121 mm)
19-7/16" (494 mm)
4-3/4" (121 mm)
15-1/16" (383 mm)
4-3/4" (121 mm)
14-7/8" (378 mm)
4-3/4" (121 mm)
10-9/16" (268 mm)
4-3/4" (121 mm)
10-9/16" (268 mm)
4-3/4" (121 mm)
21-5/8" (549 mm)
4-3/4" (121 mm)
17-5/16" (440 mm)
1-7/8"
2-11/16"
(48 mm)
(68 mm)
Side View –
Control Enclosure
14
English
Screw Hole Dimensions
(C)
(D)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
2-1/2" (64 mm)
IMPORTANT NOTE:
Make sure the installation
1-1/8"
location provides enough
(29 mm)
room for electrical and
plumbing
connections
to the control enclosure.
Follow local and national
plumbing and electrical
codes.
Form No. HWBIM-0820