The numbering of the product features refers to
the illustrations on the remote control graphics
page 18.
1A Button for rotational operation and
selection of the rotation speed
2A Button for line operation and line length
selection
3A Shock-warning reset button
4A Button for "rotation in clockwise
direction"
Initial Operation
• Protect the remote control against
moisture and direct sunlight.
• Do not subject the remote control to
extreme temperatures or variations in
temperature. As an example, do not
leave it in vehicles for longer periods. In
case of large variations in temperature,
allow the remote control to adjust to the
ambient temperature before putting it
into operation.
The remote control remains ready for operation
as long as a battery with sufficient voltage is
inserted.
For detailed information of the rotational laser
functions, see the operating instructions of the
rotational laser.
Rotational Operation
(150/300/600 min-1)
The function of the button for rotational operation
1A on the remote control is identical with that on
the rotational laser.
Each time after switching on, the rotational laser
is in rotational operation mode with average
rotational speed.
To switch from line operation to rotational
operation, press the rotational operation button
1A. Rotational operation starts with average
rotational speed.
To change the rotational speed, press the
rotational operation button 1A again until the
requested speed is reached.
RC1 Features
5A Button for "rotation in anticlockwise
direction"
6A Operation indicator
7A Outlet opening for infra-red beam
8A Battery lid
9A Latch of battery lid
10A Serial number
The accessories illustrated or described are
not included as standard delivery.
RC1 Operation
Set up the rotational laser in such a manner that
the signals of the remote control directly reach
one of the reception lenses on the rotational laser
(for this, see the operating instructions of the
rotational laser). When the remote control cannot
be pointed directly against a reception lens, the
working range is reduced. By reflecting the signal
(e.g. against walls), the working range can be
improved, even for indirect signals.
After pressing a button on the remote control, the
illuminated operation indicator 6A indicates that a
signal was sent out.
Switching the rotational laser on/off with the
remote control is not possible.
RC1 Operating Modes
The function of the button for line operation 2A
on the remote control is identical with that on the
rotational laser.
To switch to line or point operation, press the
line operation button 2A. The rotational laser
switches to line operation with the smallest
aperture angle.
To change the aperture angle, press the line
operation button 2A. The aperture angle is
increased in two steps; at the same time, the
rotational speed is increased with each step.
When pressing the line operation button 2A a
third time, the rotational laser switches to point
operation after brief post-pulsation. Pressing
button 2A again takes you back to line operation
with the smallest aperture angle.
Note: Due to inertia, it is possible for the laser to
slightly move beyond the end point of the laser
line.
-22-
Line Operation, Point Operation
(10°/25°/50°, 0°)