6.7

Troubleshooting the Printer

!
If the BAT 131 is not connected to a 12-volt battery
with at least 11.5 volts of power or the paper sensor
does not detect paper in the compartment during the
print process
Message
Action to be taken
BATTERY POWER TOO
To print, the tester must be properly
LOW TO USE PRINTER.
connected to a vehicle battery
CONNECT TO FULLY
having at least 9 volts.
R Connect to a vehicle battery with
CHARGED BATTERY
11.50 TO 16.00V
R Make sure that the clamps are
R Check that both sides of the
CONNECT TO
Tester is not connected to the
12V BATTERY
battery
LOW INTERNAL AA
Internal AA batteries are low
BATTERIES. REPLACE AA
and need to be replaced. See
BATTERIES SOON!
"Maintenance & Troubleshooting"
section.
NON 12 VOLT SYSTEM
System being tested is not 12-volts.
DETECTED
PRINTER DOOR OPEN.
Check that the door covering the
CLOSE DOOR AND TRY
printer paper is properly closed and
TO PRINT AGAIN
latched.
PRINTER OUT OF PAPER
Printer is out of thermal paper.
REPLACE WITH THERMAL
R Verify that the paper is inserted

PRINTER PAPER.

2.5 IN. DIA. MAX
R Insert a new roll of paper.
2.25 IN. WIDE MAX
R Verify that the paper sensor is
QC DATA MEMORY FULL
QC mode memory is full. Select QC
PRINT RESULTS OR
mode from the Options Menu to
CLEAR MEMORY.
clear the memory.
Robert Bosch GmbH
enough voltage to enable printing.
connected properly: red clamp to
the positive (+) terminal and the
black clamp to the negative (-)
terminal.
clamps are making contact with
the terminals.
correctly.
clean and undamaged
7.
Decommissioning
BAT 131, accessories and packaging should
be sorted for environmental-friendly recycling.
Do not dispose BAT 131 into household waste.
Only for EC countries:
The BAT 131 is subject to the European
directive 2012/19/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of BAT 131 prevents
environmental pollution and possible health
hazards.
8.

Technical data

Function / Range
Function range
Accuracy range
Workplace-related
noise-emission value (Lpa)
8.1
Battery-Test and Voltmeter
Function / Range
Operating voltage
Operating current without printer
Entry range of Cold Start Current
Battery standards
8.2
Printer Paper
Function / Range
Maximum storage period by storage in
the dark in years
Maximum storage temperature
Maximum storage humidity
| BAT 131 | 29
en
Value
0 °C – 50 °C
32 °F – 122 °F
0 °C – 40 °C
32 °F – 104 °F
< 70 dB(A)
Value
1 V – 30 V
0,4 A
50 A - 1550 A
DIN, EN, EN2
IEC, JIS, SAE
Value
< 5
30 °C
32 °F – 86 °F
<60 %
|
1 689 989 131
2019-03-02

Publicité