7.6
PROGRAMMING
STANDARD DOSES
• It is possible to enter pre-set values for the 4
group doses and water (steam).
PTo do this, it is necessary to press the key
and hold it down for at least 10 seconds
until the flashing keys switch off.
The doses are:
1CN
2CN
40 cc
60 cc
WATER
STEAM
9 sec.
0 sec.
NOTE:
A time setting of 0 seconds for steam and
water means this function will work continu-
ally.
7.7
COPIATURA DOSI
It is possible to copy the doses stored to memory for
group 1 to the doses for group 2.
This operation is performed by pressing the continu-
ous key
for group 2 and holding it down for at
least 10 seconds until the flashing keys switch off.
7.8
PROGRAMMING
OPERATING
PARAMETERS
The adjustments listed here below must ONLY
be performed by a Specialist Technical Engineer.
If you hold down the
after first entering the programming mode for the
first group, this will access the machine parameters
setting mode; this is signalled by the continuous key
or the second group, which will switch on
1. Enabling the pump if the level is enabled.
2. Enabling the software block to enter the dose
programming function.
3. Adjusting keypad brightness.
4. Enabling the hot water pump (on machines
44
1CL
2CL
50 cc
85 cc
STEAM
TEMP.
50°C
CAUTION
key of the second group,
fitted with economiser).
5. Disenabling the cup warmer
6. Restoring default settings.
1. Enabling the pump during levelling.
Use the espresso key
during levelling:
if the key
is lit, the pump is enabled together with
the level; if it is switched off, the pump is not enabled
with the level function.
2. Enabling the software block to enter the dose
programming function.
Use the long coffee key
block to programme doses (key lit) or to de-activate
the block (key off).
3. Adjusting keypad brightness.
The 2 long coffees key
used to choose the key brightness setting from 5
pre-set levels.
Use the
, key, which will flash, to change the
level, lowering it to minimum or returning it to maxi-
mum.
4. Enabling the hot water pump (machines fitted
with economiser only).
Use the hot water key
on while hot water is being delivered.
If the
key is lit, the pump will switch on while hot
water is being delivered; if it is switched off, the pump
will not switch on.
5. Starting the pump with steam (only for machine
models with timed steam or autosteam func-
tions).
The steam key
is used to set the pump to start
while steam is being dispensed.
If the key
is lit, the pump will start while steam is
being dispensed; if the key is not switched on, then
the pump will not start.
EN
to set pump enabling
to enable a software
of the second group is
to set the pump to switch
COMPACT

Publicité