8. TROUBLESHOOTING
MALFUNCTION
Pressure gauge has
Dirty filter bed
reading over 1 bar
Pressure is too low
Hair and lint strainer basket is dirty;
Pump gels too little water
Air in the pump
Poor seal on the in-take side of the
pump.
Leaking filter
Seal Defective
Pump does not run
Not plugged in
G.F.C.1/ or main circuit breaker tripped
Pump motor defective
Sand in Pool
If the sand is newly replaced, the under-
sized grains are still present
Sand in Central Valve (from back-wash)
Separation wall in filter is improperly
in-stalled
Filter bottom strainer is damaged
Air in system
For more technical information, missing
parts or in the case of a complaint,
please contact our customer service:
Dipra
65 Rue de Luzais,
38070 Saint-Quentin-Fallavier
France
Cause
Backwash the filter (position 4)
Clean the hair and lint strainer; check the
suction line and the water level
Tighten hose clamps and connecting
fittings.
Check the seal, replace if needed
Check the socket and power cord
Switch on the breaker (if it is immediately
tripped again, there is a defect in pump
or controls)
Replace the entire pump
Backwash several limes until the
backwash water is clear (position 4)
Purge into drainpipe for 30 seconds
(position 6)
Check the separation wall for proper
positioning
Replace the filter bottom strainer
Loosen, but do not remove, the
transparency cover on the filter tank to
allow any trapped air to escape. Tighten
the cover once ail of the air has escaped
Solution