The KIT SKIMO SPLIT described in this manual, is composed of an outside unit SKIMO SPLIT and an evaporator unit to be positioned
inside the cabin. The compressor - condenser unit can be installed horizontally on a wall or flat on a hood (see pictures).
The kit SKIMO SPLIT is particularly adapted to the compact machines with little room or a small driving power, to the machines the
cabin of which is far from the engine and to the users wishing a fast and easy assembly.
The SKIMO SPLIT unit has the compressor integrated and driven by an electric motor.
2 units will be linked between them by 2 hoses (high and low pressure) and electrically by a harness. See the recommendations on
the power supply with the rest of the vehicle).
The charge of refrigerant R134a will be made by a qualified and approved technician.
SKIMO
Device
SPLIT 12V
Low voltage
10,5 V
Overvoltage
18 V
Overheating of the electrical motor. The temperature of the motor went over 113°C, the unit sotp
Overheating
automatically. The unit switchs ON only when the temperature decrease to 109°C.
Overconsumption
Overconsumption of the electrical motor switch OFF automatically the unit.
Overpressure or
The unit SKIMO SPLIT integrate pressure swtich in case of pressure lower than 2 bars or higher pressure
under load
then 14 bars. In these conditions the unit STOP automatically.
Compressor
The compressor is equipped with a secutity pressure valve to ptotect the unit in case of a pressure swtich
safety
failure.
Machine safety
The unit SKIMO SPLIT is equipped with a sensor that disables the unit if the cover is opened
The SKIMO SPLIT unit is the element
positioned outside, it includes the following
components : the condenser, the drying
filter,
the
compressor,
components (electrical motor, fan, blower,
harness, fuses), but also the electric harness
of connection with the vertical evaporator
unit positioned inside the cabin.
SNDC – 274 chemin des Agriès 31860 Labarthe-sur-Lèze – France
Tél : +33 (0)5 34 480 480 - Mail :

Introduction

Electrical protections

SKIMO
SKIMO SPLIT
SPLIT 24V
80V / 12V & 80V / 24V
21 V
32 V

Technical characteristics

the
electric
414
155
– www.sndc.net
sndc@sndc.fr
EN
With horizontal mounting only the connectings on the
TOP
The battery tension went lower than these values,
71 V
the unit stop automatically
The battery tension went above these values, the
100 V
unit stop automatically.
205
420
410
Complement