Important; Checking Functioning; Maintenance; Spare Parts - Lotus BMT-64G Instructions Pour L'installation Et L'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The only operation necessary is the substitution of the nozzle according to the type of gas.
It is therefore necessary to unscrew the screws as specified in the previous point; with a suitable spanner unscrew the
fitting and substitute the nozzle with a suitable one. With the right nozzle, the flame must lap the thermocouple.

Important!

After having made the conversion to another type of gas, it is necessary to update the data plate, indicating the type of
gas for which the appliance has been converted.
The appliance contains the instructions necessary for use.
Check the appliances for gas leaks.
Examine the flame of the pilot burner; it must lap the thermocouple and be blue, otherwise examine the nozzle of
the pilot burner.
Check the lighting and flame of the main burner.
We urge the user to follow the instructions when using the appliance.
With prolonged use of the appliance, it is essential to carry out regular maintenance for the safe functioning of the
appliance; we therefore recommend drawing up a contract for after sales service.
Maintenance must be done only by specialised personnel, observing the norms in force and our indications.
It is possible to substitute parts such as the valve, the piezoelectric lighter or gas pipes very simply. To substitute the
parts, proceed as follows:
Valve: after removing the front panel, unscrew the screwed fittings of the gas connections, remove the fitting and
take out the thermostat bulb, then substitute the faulty parts, installing the new ones in order.
To substitute the thermocouple, unscrew the pilot burner fitting, likewise the valve fitting and substitute the
element.
The spark plug must be unscrewed and substituted.

Attention!

Before lighting the appliance, it must be washed with water and dish-washing detergent, rinsed thoroughly and filled
with water up to the level indicated by the mark on the back of the water container.
DO NOT START UP THE APPLIANCE WITH THE WATER CONTAINER EMPTY.
Before using the appliance, it is necessary to clean it carefully, especially the water container (see paragraph "cleaning
and care").
Check the connection of the appliance and start it up following the instructions, "Instructions for use".
Attention!
Use the appliance only under surveillance.
The system must be connected to a drinking water supply with the following characteristics. Failure to do so
automatically invalidates the guarantee
Total hardness: 0,5 to 5°F to prevent the build-up of lime-scale
Pressure: 50 to 250 kPa (0,5-2,5 bar).
Chlorine ion concentration (Cl-): not more than 10 ppm (acceptable value) to avoid damaging the internal steel
elements
pH: over 7
Electrical conductivity: 50 to 2000 μS/cm (20°C)

Lighting the pilot burner

Check that the thermostat knob is in position
Keeping the knob pushed down, press the piezo button repeatedly. The flame lights automatically and can be seen
through the inspection hole in the front panel. After lighting, hold the knob down for another 20-30 seconds, to allow
GB
IT

CHECKING FUNCTIONING

MAINTENANCE

SPARE PARTS

STARTING UP

WATER SUPPLY CHARACTERISTICS

LIGHTING THE BURNER

.
27
IE
CH

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Bmt-66g

Table des Matières