7. CONTROL BOARD

OPERATION This electronic device manages the automatic pressed wood BRIQUETTES feed system (ALS – Briquette's Automatic
Loading System).
7.1.

USER MENU

MENU The selection of MANUAL and AUTOMATIC mode occurs by pressing and holding the P1 button. The operation mode status will
be shown on the display. Enter the MENU by pressing the P2 button (next) or P3 button (previous).
SLEEP MENU Pressing the P6 button you will access the SLEEP MENU. Press the P6 button and set the time after which the stove switch
from AUTOMATIC to MANUAL mode by acting on the P4 – P5 button (Off – 1,2,3,4,5,6 h). Press the P6 button to confirm the selection.
Press the P1 button to return to the previous menu. Press the P2 and P3 buttons simultaneously to activate the SLEEP mode. "Switch-off
in --- minutes" appears on the display. The SLEEP feature can ONLY be activated from the AUTOMATIC mode. Press and hold the P1
button to disable the SLEEP feature,and move to MANUAL mode.
LANGUAGE MENU Pressing the P2 button you will access the LANGUAGE MENU. Press the P6 button and set the menu language by
pressing the P4 – P5 button (ITALIAN – ENGLISH – GERMAN – FRENCH - SPANISH). Press the P6 button to confirm the selection.
Press the P1 button to return to the previous menu.
BUZZER MENU Pressing the P2 button you will access the BUZZER MENU. Press the P6 button and set the acoustic signal status by
pressing the P4 – P5 button (ON - OFF). Press the P6 button to confirm the selection. Press the P1 button to return to the previous menu.
DISPLAY MENU Pressing the P2 button will access the DISPLAY MENU. Press the P6 button and set the brightness by pressing the P4
– P5 button (from 10 to 31). Press the P6 button to confirm the selection. Press the P1 button to return to the previous menu.
Pressing the P2 button you will access the TECHNICAL MENU, a menu which is ONLY enabled for Technical Support personnel.
P1
P2
P3

8. FLUE

Essential requirements for correct appliance operation:
the internal section must preferably be circular;
the appliance must be thermally insulated and impermeable and built with suitable materials which are resistant to heat, combustion
products and any condensation;
there must be no narrowing and vertical passages with deviations must not be greater than 45°;
if already used, it must be clean;
the technical data from the instruction manual must be respected;
If the flues are of a square or rectangular section, the internal edges must be rounded with a radius of not less than 20 mm.
For the rectangular section, the maximum ratio between the sides must be ≤ 1.5.
A section which is too small causes a reduction in draught. A minimum height of 4 m is advisable.
The following materials are FORBIDDEN and compromise the good operation of the appliance: asbestos cement, galvanised steel, rough
and porous internal surfaces.
The minimum section must be 4 dm
dm
(for example 25x25 cm) for appliances with a diameter of more than 200 mm.
2
The draught created by your flue must be sufficient but not excessive.
A section of the flue which is too large can present a volume which is too large to heat and therefore cause operating difficulties for the
appliance; to avoid this, it is necessary to intubate the appliance for its entire height. A section which is too small causes a reduction in
draught.
24
P6
Picture 1 at page 62
shows some example solutions.
(for example 20x20 cm) for appliances whose pipe dimensions are less than 200 mm, or 6.25
2
MANUAL
AUTOMATIC
LANGUAGE
P4
P5
TECHNICAL
SLEEP
Off - 1 - 2 - 3 - 4 - 5 - 6 h
IT - EN - DE - FR - SP
BUZZER
On - Off
DISPLAY
10 - 30 %
Code ...