If you wish to install the filtering version hood, drill a hole in the wall structure where it will be mounted, of a suitable size to allow purified
air to exit the structure. This hole should be connected to the hood's air outlet fitting with a suitable pipe to protect the inside of the struc-
ture from humidity and residues of fat particles.
G
Phase
page 8
• Electrically power the hood in accordance with regulations in force.
OPERATION
WHEN SHOULD THE HOOD BE SWITCHED ON AND OFF?
Switch on the hood at least one minute before starting to cook: this enhances the airflow to convey fumes and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all vapours and odours. If required, by means of the Timer function, it is possible
to set hood auto switch-off after 15 minutes of operation.
WHICH SPEED IS TO BE SELECTED?
The first speed is a low consumption energy-saving way of keeping the air clean, the second speed is used in normal conditions, and the third
speed is used when there are strong odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The hood is assembled with two different types of filters: metal ones (washable) and active carbon ones (non-washable). The former must be
cleaned every 30 hours of use, the latter are to be replaced every 3-4 months, depending on the use of the hood.
For further information, please read the chapter regarding "Maintenance" on page 23.
USE OF ELECTRONIC PUSH BUTTON CONTROL PANEL
Timer/Filters alarm
Pressing the key with the motor active at any speed activates the Timer function: this function determines the auto switch-off of the
hood after 15 minutes of operation. Activation of the function is signalled by a RED flashing light.
With the Timer function active, the hood can still be switched off by the user at any time by pressing the key
automatically disabled and the RED light will turn off. Should the speed be changed with the Timer function active, the latter will be
automatically disabled.
To disassemble and assemble the anti-grease metal filters, refer to the instructions on drawing
Mode button (ON/OFF)
Pressing the key switches on (or off ) the hood motor: it starts at the previously selected speed prior to switching it off (desired speed
function). Should you wish to use a different speed, set if by using the + and - keys.
Button +
By pressing the key, the motor speed increases. Speeds 1, 2 and 3 are displayed by the number of LEDs switched on, excluding the light
and timer LEDs. The + key in the version with 4 speeds has an intermittent light: the 4th speed or intensity is timed and after approximate-
ly 7 minutes the motor automatically switches to 3rd speed.
Button -
By pressing the key, the motor speed reduces. Speeds 1, 2 and 3 are displayed by the number of LEDs switched on, excluding the light
and timer LEDs.
Light button
ON: light on (lit button) OFF: light off
USING THE RADIO CONTROL (OPTIONAL)
ACTIVATING RECEIVER BOARD FOR RADIO CONTROL
The hood is supplied with a receiving card for the 4-channel remote control: this receiver is disabled by default in order to prevent any electroma-
gnetic interference between other devices from causing hood malfunction.
If the remote control (optional) is purchased, you must activate the receiver by following the procedure hereunder:
• Simultaneously press the
LEDs start flashing
• Release the two keys and, within 5 seconds, press the
procedure is confirmed when all LEDs have fixed lights, until releasing the
If required, the above-mentioned procedure also applies to disabling the receiver.
WARNINGS WHEN USING THE RADIO CONTROL
Place the hood away from sources of electromagnetic waves (e.g. microwave ovens), which could interfere with the radio control and, consequently,
with the hood electronics. The maximum operating distance is 5 metres; the distance may vary according to the presence of electromagnetic inter-
ference from other devices. Radio control operated at 433.92MHz.
and
keys on the hood push-button control panel for at least 2 seconds, until all push-button control panel
key on the push-button control panel for at least 2 seconds. Correct execution of the
key
21
: the function will be
I
on page 9.