the heater using the ON/OFF button, switch off the main switch and
remove the plug from the socket.
ATTENTION! Day and time are deleted if the electricity is cut off. This
happens not only when the plug is pulled out of the socket, but also if the
main switch is set to O (OFF). The timer settings however are stored.
When the electricity is restored and the timer settings are entered, then
you need to reset the day and hour settings immediately; otherwise the
time will begin at 0.00!
If you do not enter any orders for approx. 15 seconds, the display will turn off.
Pressing any random button will reactivate the display.
Switching off
If you are not using the heater, you must switch it off using the main switch (you
press O) and remove the plug from the socket. Doing this will erases all the
settings, also day and time. Only the timer settings are stored.

Safety feature

The Valencia atmospheric fireplace is equipped with an overheating safeguard. In
case of internal overheating, the overheating safeguard will switch the heater off.
This may occur if the heater cannot give off enough heat or if it cannot draw in
enough fresh air. As mentioned above, this is generally caused by (partially)
covering the heater, obstructing the air intake and/or outlet grills or installing the
heater too close to a wall or something similar.
If this happens, turn the fireplace off by switching the main switch to O and remove
the plug from the socket. Leave the fireplace to cool down for at least 15 minutes
and remove the cause of overheating. You can then switch the fireplace back on.
If the device overheats again or you cannot ascertain the reason for this, take the
fireplace to your service point to be checked/repaired.
Important! For safety reasons the fire will not automatically restart after
overheating. Check whether conditions are safe before switching it on! So never
switch on the heater by means of a timer and never connect it to a power supply
that regularly switches on and off.

Cleaning and maintenance

Always remove the plug from the socket and let the fireplace cool down before
cleaning or touching.
The Valencia atmospheric fireplace does not need much maintenance. Always keep
the in- and outlet openings clean and dust-free. Use a soft cloth or a soft brush to
clean the outside of the metal case. The glass plate can also be cleaned with a soft
cloth. Do not use abrasive cleaning fluids or special glass cleaners!