Display Messages

The following table explains the various messages that appear in the display.
Message
Error code(s)
CANNOT LINC
C78:11/C78:12
NO SIGNAL
C78:04
C78:22
C78:31
BUS FULL
C78:15
LOOP CONNECT
C78:03
NEW CONNECT
FUNC. Locked
Select FUNC.
Input Occupied
Off Processing
Cause and/or remedy
The receiver can't establish a LINC with a component because of an existing LINC between
the receiver and another component. Cancel the LINC between the receiver and the other
component.
No signal is output from the selected component. Verify that the signal is output from the
component (e.g., by recording from the component).
The format of the input signal is not supported.
The communication between the receiver and the selected component is unstable. Or, the
format of the input signal is not supported. Check the condition and the signal format of
the selected component.
The signal bus within the i.LINK configuration is full and no more signals can be output
from the receiver. Cancel the LINC between the component and the receiver.
The i.LINK connection is looped. Check the connection (see page 26).
An i.LINK component has been connected to or disconnected from the i.LINK
configuration. Wait several seconds for the indication to turn off.
You can't select a component because the LINC between the other component and the
receiver is currently established. Cancel the LINC between the other component and the
receiver.
Select another component.
Cancel the LINC between the other component and the receiver.
While the i.LINK Control function is activated, the corresponding i.LINK component turns
off automatically when you turn off the receiver. However, it may take a while for the
component to turn off and no operations are possible on the receiver while this indication
is flashing. Wait several seconds for the indication to turn off.