Kratki PANTHER MERLOT Manuel D'utilisation Et D'installation page 70

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical Specification
Gas group
Type
Nominal connection
pressure
Gas pressure behind the
regulator for the rated load
Gas pressure behind the
regulator for minimum
load
Rated thermal load, accor-
ding to H
i
Rated minimum load,
according to H
i
Consumable gas stream for
rated (maximum) heat load
Gas consumption for
minimum heat load
Efficie y class
NOx concentration class
Gas nozzle
Gas nozzle designation
70
I2E(20), I2H(20)
G20 
[mbar]
20
19,0
[mbar]
[mbar]
5,0
[mbar]
5,2
[mbar]
2,7
[m
/h]
0,57
3
[m
/h]
0,29
3
[-]
2
[-]
4
[mm]
1,90
[-]
NG1.9
I2L(25)
I2E+(20/25)
G25 
G20/G25 
NG
25
23,5
19,0/23,5
Regulator Blocked
6,5
5,2
2,7
0,62
0,57/0,62
0,32
0,29/0,32
2
4
1,90
NG1.9
I3B/P(30)
20/25
30
5,0/6,5
5,2
2,7
2
4
5
1,90
NG1.9

Publicité

Table des Matières
loading

Table des Matières