Replacement of batteries
Batteries in the receiver, remote control or the power supply module can overheat, spill or even cause
an explosion. Do not use batteries that have been exposed to the sun, moisture, heat or vibration.
Install only batteries of the same type and the same manufacturer. Do not install new batteries with
worn ones. The remote control is powered by two AAA batteries. The B6R-R8U receiver and the
G60-ZB90 power module are powered by four AA batteries 1.5V. The battery life in the case of the
remote control and the receiver is estimated at about 1 heating season. The device manufacturer re-
commends the use of alkaline batteries because of the lower risk associated with unsealing. It is also
permissible to use rechargeable batteries. When removing batteries, do not use tools that can cause
a short-circuit. Replacing batteries with conductive objects can permanently damage the electronic
components of the remote control and the receiver.
Replacement of the batteries in the remote control:
• Remove the cover located on the rear of the remote control.
• Gently remove the used batteries from the remote control.
• Install new AAA batteries observing the polarity markings (+/-).
• Replace the cover on the back wall of the remote
Replacing batteries in the receiver/power supply module:
• Open the cabinet door panel.
• Carefully remove the B6R-R8U receiver/G60-ZB90 power module.
• Remove the cover.
• Remove the used four AA batteries and install new, paying attention to the
• polarity markings (+/-) on the receiver/power module.
• Replace the cover on the cover receiver/supply module.
NOTE!!!
Replacing batteries in the receiver/power supply module can only be done on a cool stove with
the gas supply cut off.
NOTE!!!
Batteries are classified as hazardous chemical waste, so, after using them, they should not be
disposed of with other household waste.
Maintenance
NOTE!!!
All maintenance work should be carried out on a cool stove with gas supply off and disconnec-
ted power supply.
NOTE!!!
Maintenance of the gas stove and the combustion air system can only be done by a qualified
service technician.
• The device requires periodic inspection at least once a year.
• Cleaning the chimney system and a review should be conducted at least once a year.
• Glass with cracks and scratches should be immediately replaced with new ones.
• It is forbidden to make any changes in the design of the device.
• Stoves should not be cleaned with caustic agents.
• When replacing individual components, use only original spare parts available from the manu-
facturer.