USTERKA
The device will not start
(no audible confi mation
of the ignition procedure)
No voltage on the
controller coil (there are no
specific„clicks")
No spark at the electrode
No control flam
After lighting the control
flam , spark still appears at
the electrode
The control flam
extinguishes automatically
Weak control flam
PROPONOWANE CZYNNOŚCI
• Replace the batteries in the remote control and the receiver.
• If the receiver is powered by the power module assess its perfor-
mance.
• Reset the receiver and program a new transmission code.
• Make sure the receiver antenna is properly installed and not
damaged.
• Make sure the switch cord in the gas control module is not
damaged.
• Short cyclical signals appearing when you try to switch on the stove
indicate the need to replace the batteries in the receiver.
• For one long beep:
- Make sure that the switch on the connecting cable from the gas
control module with the receiver is set to „I". (Option)
- Check that the cable connecting the receiver to the gas control
module is not damaged.
- If the stepper motor is not working properly, replace the gas control
module.
- If the coil of the gas control unit is not working properly, replace
the module.
- If the micro-switch of the gas control module is not working proper-
ly, replace the module
• Check the cable connection between the receiver and the electrode.
• Check that the electrode is not damaged.
• Check the operation of the sparker.
• Check that there is no system breakdown.
• If the ignition components are working properly and the fi ing
procedure does not start:
- Press the „RESET" button on the receiver.
- If it is possible, shorten the cable between the receiver and the
electrode.
- Add a grounding cable between the controller and the control
burner.
• Make sure that the gas shut-off alve is open.
• Repeatedly make attempts to ignite the stove.
• Check that the pressure in the gas installation is appropriate.
• Check the connection between the breaker and the receiver.
• Check the connection between the breaker and the controller.
• In the case of damage to the electronic amplifie , replace the
receiver.
• Make sure the thermocouple sensor is operating and
• Properly connected to the gas control module.
• Make sure the flame ontrol is capable of heating the temp. sensor.
• Check that the gas valve of the gas control module is not damaged.
• Check the gas pressure in the control flam .
67