Balluff BFT-003-A0C- Série Notice D'utilisation page 22

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Temperature sensor
BFT _ _ _ _-_ _003-_ _ _A0C-_ _
Menu
Display mode
▲ ▼
Hold down MENU key
Programming mode
▲ ▼
SP1 / FH1
Value
▲ ▼
RP1 / FL1
Value
▲ ▼
SP2 / FH2
Value
▲ ▼
RP2 / FL2
Value
▲ ▼
EF
RES
▲ ▼
DS1
▲ ▼
DR1
▲ ▼
DS2
▲ ▼
DR2
▲ ▼
OU1
▲ ▼
OU2
▲ ▼
UNIT
▲ ▼
SETR
OFS
▲ ▼
DISM
▲ ▼
DISR
▲ ▼
RHL
▲ ▼
PAS
▲ ▼
TAG
▲ ▼
END
END
▼ ▼
▼ ▼
Display mode
8
english
Min: MBA + 0.5 % of span, max: MBE
Min: MBA, max: SP1 -0.5 % of span
Min: MBA + 0.5 % of span, max: MBE
Min: MBA, max: SP2 -0.5 % of span
Yes / No
Reset to factory settings
Value
0...50 s
Value
0...50 s
Value
0...50 s
Value
0...50 s
PARA
HNO, HNC, FNO, FNC
PARA
HNO, HNC, FNO, FNC
Unit
°C, °F
4 mA / 0 V
Value
▲ ▼
20 mA / 10 V
Value
Value
Offset setting 3 % of span
ACT, HIGH, LOW, OFF, SP1/FH1, RP1/FL1,
PARA
SP2/FH2, RP2/FL2
Yes / No
Rotate display by 180°
Yes / No
Reset HIGH, LOW
Value
Password
Value
Measuring location number
MBA = Measuring range start
MBE = Measuring range end
MBA +25 % of span
MBE -25 % of span
Factory setting:
MBE
MBE -10 %
MBE
MBE -10 %
0 s
0 s
0 s
0 s
HNO
HNO
Job-specific
MBA
MBE
0 %
ACT
w/o
w/o

Publicité

Table des Matières
loading

Table des Matières