11. Technical data

11.1 Identification plate

The identification plate is on the back of the actuator plate A2 for urinals. This product
conforms to all the appropriate EU guidelines.

11.2 Actuator plate A2 for urinals, mains version

Article number
Rated voltage
Power consumption
Temperature range
Operating temperature
Battery remote control

11.3 Actuator plate A2 for urinals, battery version

Article number
Battery actuator plate
Battery remote control
Temperature range
Operating temperature
Warranty
54
WD5007 013 000
WD5007 023 000
Prim: 110-240 VAC, 50/60 Hz
Sec: 16.5 VDC
8.5 VA
0-50 °C
Button cell CR2025
WD5006 013 000
WD5006 023 000
6V DL223/EL223/CRP2
Button cell CR2025
0-50 °C
Our warranty terms can be found in our General Terms
and Conditions (GTC) at www.pro.duravit.com