Activating/Deactivating The Cleaning Function (Mains Version Only) - DURAVIT DuraSystem Série Notice D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

The status LED flashes 2 times on the control panel. The dynamic flush volume is
activated.
The status LED flashes once on the control panel. The dynamic flush volume is deacti-
vated.
If 2 main flushes take place within 30 seconds when the "Dynamic flush volume" is
activated, the flushing time of the subsequent flush(es) is halved. If the main flushing
time is set to 6 seconds, the flush is reduced to 3 seconds. Then if in turn no flush
takes place for more than 2 minutes, the system automatically triggers a cleaning
flush and returns to normal mode.
Dynamic flush volume
Table 5: Dynamic flush volume

Activating/deactivating the cleaning function (mains version only)

The cleaning function allows you to interrupt the automatic triggering of flushes for up
to 30 minutes so that the cleaning agent can take effect. You can activate the cleaning
function and also deactivate it again via your remote control (see table 6: Cleaning
function).
> Press the "Cleaning function" preselection button on your remote control.
The status LED flashes 5 times on the control panel. The cleaning function is activated/
deactivated. The status LED flashes continuously on the control panel when the clean-
ing function is activated.
If you do not deactivate the cleaning flush yourself, the system automatically returns
to normal mode after 30 minutes.