Problem
Manual cleaning function of the spray wand
The spray wand ret-
racts automatically.
Automatic self-cleaning
Water is dripping
out of the retracted
spray wand.
10. Technical Data
Article number
Rated voltage
Frequency
Nominal power consumption
Standby power consumption
Maximum current
Temperature range
Operating temperature
Water temperature
Incoming water pressure
Water consumption in spray mode
Protection degree
Integrated safety device
Potential cause
The function automatically
stops after 2 minutes.
The spray wand is clea-
ned automatically before
and after washing.
Solution
This is normal.
This is normal.
611.00 00 2 00 4300
220 - 240 V
50/60 Hz
1050 W
< 0.5 W
6.8 A
4 - 40 °C
32 - 40 °C
0.07 - 0.75 MPa (0.7 - 7.5 bar)
0.35 - 0.60 l/min
IP X4
Protection against water spray from all
sides
EN13077 - type AB
Ch.
EN
35