HBM MP60DP Manuel D'emploi page 17

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

PME−MP60DP
Status 1
Bits
Name
0
Ovfl
1
AOutOvfl
2
ScalErr
3
EEPROMErr
4
Limit1
5
Limit2
6
Limit3
7
Limit4
8
PAR1
9
PAR2
10..14
res
15
MViO
Tab 6.5:
Contents of status 1
1)
Meaning of MViO:
NOR operation of: MesswOvfl, SkalErr, EEPROMErr.
MesswOvfl is the OR operation of ADCOvfl, HardwOvfl, GrossOvfl, NetOvfl
The parameter set number is coded in 2 bit binary:
Bit 8 Bit 9
Parameter set no.
0
0
1
0
0
1
1
1
Status 2
Double status word 2 returns detailed error flagging.
Bits
Name
0
HardwOvfl
1
ADCOvfl
2
GrossOvfl
3
NetOvfl
4
AOutOvfl
5
MaxOvfl
6
MinOvfl
7
NegOvfl
8
Limit1
9
Limit2
10
Limit3
11
Limit4
12
ScalInError
13
ScalOutError
14
GainError
15
InitError
16
TransducerError
17..31
Tab 6.6:
Contents of status 2
A0623-6.1 en/de/fr
Measured value in order
1
2
3
4
res
Meaning
measured values overflow
analogue output overflow
scaling defective
EEPROM (parameter set) defective
status of limit switch 1
status of limit switch 2
status of limit switch 3
status of limit switch 4
active parameter set bit 1
active parameter set bit 1
reserved
Meaning
hardware overflow
ADC overflow
gross signal overflow
net signal overflow
analogue output overflow
maximum overflow
minimum overflow
overflow in negative direction
status of limit switch 1
status of limit switch 2
status of limit switch 3
status of limit switch 4
scaling input invalid
scaling output invalid
nominal value exceeded
works calibration defective
transducer error
reserved
1)
(if bit 0,2,3=0)