Make Electrical Connection - Jenn-Air JID4436ES Instructions D'installation

Masquer les pouces Voir aussi pour JID4436ES:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3. Tighten all of the screws connecting the ducting and use
metal duct tape to seal all duct joints.
4. Using the proper drill type, drill 4 holes aligned through the
motor housing mounting brackets (2 holes each bracket) into
the floor. Using 4 screws (not supplied) for floor type, secure
the blower motor assembly to the floor.
A
B
A. Blower motor assembly bottom duct extension
B. 3
/
" x 10" (8.3 cm x 25.4 cm) rectangular duct (not supplied)
1
4
See NOTE.
C. Recirculation duct assembly
D. Mounting screws (4)
E. Cover – recirculation duct assembly
F. Fasteners – cover (2)
G. Screws (4) (not supplied)
NOTE: The length of the rectangular duct is determined by
the dimension from the blower motor bottom duct extension
to the duct extension of the recirculation duct assembly.
5. Assemble Recirculation Kit through the cabinet side to
the blower motor assembly venting outlet.
NOTE: Ensure the 2 charcoal filters are installed inside
the recirculation duct assembly housing.
6. Use metal duct tape to secure and seal all duct joints.
16
G
D E
F
C
D

Make Electrical Connection

WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
Electronics Connections – Cooktop to Electrical Box
1. Disconnect power.
2. Use a T20
TORX
driver to remove 2 screws and the
®
®
electronics connection box cover and set aside.
A
B
C
A. Electronics box cover
B. Screws (2)
C. Electronics box

Publicité

Table des Matières
loading

Table des Matières