Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools
listed here.
Tools Needed
Tape measure
■
Phillips screwdriver
■
Flat-blade screwdriver
■
Level
■
Drill
■
T20
TORX
drivers
®†
®†
■
Parts Supplied
Check that all parts are included.
Cooktop assembly
■
Blower housing assembly with electronic box assemblies
■
(4) Cooktop mounting brackets (corners)
■
Grease filter
■
(11) M4 x 9.5 mm screws (ducting and electrical box
■
strain reliefs)
(16) M4 x 12 mm screws (cooktop mounting brackets
■
to cabinet)
(4) M6 x 16 mm screws (blower motor assembly to
■
cabinet floor)
(4) M5 x 10 mm flat-head screws (mounting feet to
■
blower motor assembly bottom)
(4) M5 x 50 mm cap head screws (cooktop-to-cooktop
■
mounting brackets)
(4) M5 lock washers
■
(4) M5 flat washers
■
(2) UL listed or CSA approved M\," (2.2 cm) strain relief
■
Rectangular duct 2-piece telescoping (blower assembly
■
to cooktop)
Foam strip
■
Parts Needed
A UL listed or CSA approved strain relief for M\," (2.2 cm)
■
knockout
(4) UL listed wire connectors for 8-gauge wires
■
For vented installations:
3Z\v" x 10" (8.3 cm x 25.4 cm) metal ducting
■
Jenn-Air
wall cap:
®
■
Jenn-Air
3¼" x 10" (8.3 cm x 25.4 cm) Surface Wall Cap
®
Damper part number A403.
See the "Assistance or Service" section in your Use and
Care manual to order.
For non-vented installations:
Recirculation Kit part number W10807915 (See the
■
"Assistance or Service" section in your Use and Care
manual to order.)
a. Recirculation duct housing
b. (4) Mounting screws
c. (2) Charcoal filters
d. Recirculation housing cover
®TORX and T20 are registered trademarks of Acument Intellectual Properties, LLC.
†
INSTALLATION REQUIREMENTS
Marker or pencil
■
Pliers
■
Jigsaw
■
Caulking
■
Aluminum duct tape
■
e. (2) Mounting screws – cover
f.
Duct extension
g. (4) Mounting screws – duct extension
For non-vented installations side recirculation only:
3Z\v" x 10" (8.3 cm x 25.4 cm) metal duct – length required
■
is determined by the distance from the exhaust outlet to the
back flat surface of the Recirculation Kit housing.
Check local codes. Check existing electrical supply. See the
"Electrical Requirements" section.
It is recommended that all electrical connections be made by
a licensed, qualified electrical installer.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
When installing the cooktop, use the minimum dimensions given.
To eliminate the risk of burns or fire by reaching over the
■
heated surface units, cabinet storage space located above
the surface units should be avoided. If cabinet storage is to
be provided, the risk can be reduced by installing a range
hood that projects horizontally a minimum of 5" (12.7 cm)
beyond the bottom of the cabinets.
Use the countertop opening dimensions that are given
■
with these Installation Instructions. Given dimensions are
minimum clearances and provide 0" (0 cm) clearance.
The model/serial/rating label is located on the front face of
■
the electrical junction box cover.
A
A. Model/serial/rating label location
Grounded electrical supply is required. See the "Electrical
■
Requirements" section.
If cabinet has drawers, drawers will need to be removed
■
and drawer fronts installed on front of cabinet.
NOTE: The exhaust system is for outside venting. For
non-vented (recirculating) installation, see "For non-vented
(recirculating) installations only" in the "Connect Vent System"
section. Recirculating Kit part number W10807915 is available
from your dealer or an authorized parts distributor.
IMPORTANT: An undercounter built-in oven cannot be installed
under this product.
3