30" (76.2 CM) DOUBLE OVEN DUAL FUEL RANGES
INSTRUCTIONS POUR L'INSTALLATION DES CUISINIÈRES
À BI-COMBUSTIBLE ET FOUR DOUBLE DE 30" (76,2 CM)
RANGE SAFETY............................................................................. 2
INSTALLATION REQUIREMENTS ............................................... 3
Tools and Parts............................................................................ 3
Location Requirements ............................................................... 3
Electrical Requirements - U.S.A. Only ........................................ 5
Electrical Requirements - Canada Only ...................................... 6
Gas Supply Requirements .......................................................... 7
INSTALLATION INSTRUCTIONS ................................................. 8
Unpack Range............................................................................. 8
Adjust Leveling Legs ................................................................... 8
Install Anti-Tip Bracket ................................................................ 9
Electrical Connection - U.S.A. Only .......................................... 10
Make Gas Connection............................................................... 15
Verify Anti-Tip Bracket Location ............................................... 16
Level Range ............................................................................... 16
Electronic Ignition System......................................................... 17
Complete Installation................................................................. 17
GAS CONVERSIONS ................................................................... 18
LP Gas Conversion.................................................................... 18
Natural Gas Conversion ............................................................ 19
Moving the Range ..................................................................... 21
IMPORTANT:
Save for local electrical inspector's use.
IMPORTANT :
À conserver pour consultation par l'inspecteur local des installations électriques.
W10162495A
All manuals and user guides at all-guides.com
INSTALLATION INSTRUCTIONS
Table of Contents/Table des matières
SÉCURITÉ DE LA CUISINIÈRE ...................................................22
EXIGENCES D'INSTALLATION...................................................24
Outils et composants .................................................................24
Exigences d'emplacement.........................................................24
Spécifications électriques ..........................................................26
Spécifications de l'alimentation en gaz .....................................26
INSTRUCTIONS D'INSTALLATION ............................................28
Déballage de la cuisinière ..........................................................28
Réglage des pieds de nivellement.............................................28
Installation de la bride antibasculement ....................................28
Raccordement au gaz................................................................29
Réglage de l'aplomb de la cuisinière.........................................30
Système d'allumage électronique..............................................30
Achever l'installation ..................................................................31
CONVERSIONS DE GAZ..............................................................32
Déplacement de la cuisinière.....................................................35

Publicité

Table des Matières
loading

Sommaire des Matières pour Jenn-Air JDR8895BAB

  • Page 1: Table Des Matières

    All manuals and user guides at all-guides.com INSTALLATION INSTRUCTIONS 30" (76.2 CM) DOUBLE OVEN DUAL FUEL RANGES INSTRUCTIONS POUR L’INSTALLATION DES CUISINIÈRES À BI-COMBUSTIBLE ET FOUR DOUBLE DE 30" (76,2 CM) Table of Contents/Table des matières RANGE SAFETY................2 SÉCURITÉ DE LA CUISINIÈRE ...........22 INSTALLATION REQUIREMENTS ..........
  • Page 2: Range Safety

    All manuals and user guides at all-guides.com RANGE SAFETY Your safety and the safety of others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This is the safety alert symbol.
  • Page 3: Installation Requirements

    All manuals and user guides at all-guides.com In the State of Massachusetts, the following installation instructions apply: Installations and repairs must be performed by a qualified or licensed contractor, plumber, or gasfitter qualified or licensed by the State of Massachusetts. If using a ball valve, it shall be a T-handle type.
  • Page 4 All manuals and user guides at all-guides.com Cabinet opening dimensions that are shown must be used. Product Dimensions Given dimensions are minimum clearances. The floor anti-tip bracket must be installed. To install the anti- tip bracket shipped with the range, see “Install Anti-Tip Bracket”...
  • Page 5: Electrical Requirements - U.s.a. Only

    All manuals and user guides at all-guides.com Range may be installed with zero clearance to combustible construction at the rear and on the sides below the cooktop. Electrical Requirements - U.S.A. Only If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes.
  • Page 6: Electrical Requirements - Canada Only

    All manuals and user guides at all-guides.com If connecting to a 4-wire system: Electrical Requirements - Canada Only This range is manufactured with the ground connected to the neutral by a link. The ground must be revised so the green ground wire of the 4-wire power supply cord is connected to the WARNING cabinet.
  • Page 7: Gas Supply Requirements

    All manuals and user guides at all-guides.com Gas Supply Requirements Flexible metal appliance connector: WARNING If local codes permit, a new CSA design-certified, 4 to 5 ft (122 to 152.4 cm) long, ½" (1.3 cm) or ¾" (1.9 cm) I.D., flexible metal appliance connector may be used for connecting range to the gas supply line.
  • Page 8: Installation Instructions

    All manuals and user guides at all-guides.com Line pressure testing above ½ psi gauge (14" WCP) Burner Input Requirements The range and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of Input ratings shown on the model/serial rating plate are for that system at test pressures in excess of ½...
  • Page 9: Install Anti-Tip Bracket

    All manuals and user guides at all-guides.com Install Anti-Tip Bracket 1. Remove the anti-tip bracket that is taped inside the upper Floor Mounting oven with the literature package. 2. Determine which mounting method to use: floor or wall. If you have a stone or masonry floor you can use the wall mounting method.
  • Page 10: Electrical Connection - U.s.a. Only

    All manuals and user guides at all-guides.com Electrical Connection - U.S.A. Only Power Supply Cord Direct Wire WARNING WARNING Electrical Shock Hazard Electrical Shock Hazard Disconnect power before servicing. Disconnect power before servicing. Use 8 gauge copper or 6 gauge aluminum wire. Use a new 40 amp power supply cord.
  • Page 11 All manuals and user guides at all-guides.com Style 2: Direct wire strain relief Feed the flexible conduit through the strain relief, allowing enough slack to easily attach wiring to the terminal block. Use Phillips screwdriver to remove screws and slide cord/conduit plate down and out.
  • Page 12 All manuals and user guides at all-guides.com 4-wire connection: Power Supply Cord Use this method for: 4. Use Phillips screwdriver to connect the green ground wire from the power supply cord to the range with the ground-link New branch-circuit installations (1996 NEC) screw.
  • Page 13 All manuals and user guides at all-guides.com 3-wire connection: Power Supply Cord Direct Wire Installation: Copper or Aluminum Wire Use this method only if local codes permit connecting chassis This range may be connected directly to the fuse disconnect or ground conductor to neutral wire of power supply cord.
  • Page 14 All manuals and user guides at all-guides.com 3. Pull the conduit through the strain relief on cord/conduit plate 5. Use Phillips screwdriver to connect the bare (green) ground on bottom of range. Allow enough slack to easily attach wire to the range with the ground-link screw. The ground wire wiring to the terminal block.
  • Page 15: Make Gas Connection

    All manuals and user guides at all-guides.com 2. Attach terminal lugs to line 1 (black), bare (green) ground, and line 2 (red) wires. Loosen (do not remove) the set screw on the Make Gas Connection front of the terminal lug and insert exposed wire end through bottom of terminal lugs.
  • Page 16: Verify Anti-Tip Bracket Location

    All manuals and user guides at all-guides.com 4. Gas supply pipe must be located within clearance area as shown in the “Cabinet Dimensions” illustration in “Location Verify Anti-Tip Bracket Location Requirements” section. 1. Move range close to cabinet opening. 2. Remove cardboard or hardboard from under the range. Using 2 or more people, gently move range into its final position.
  • Page 17: Electronic Ignition System

    All manuals and user guides at all-guides.com Hold the knob stem in the low position using a pair of pliers. Use an ¹⁄₈" (3.0 mm) flat-blade screwdriver to turn the screw located in Electronic Ignition System the center of the control knob stem until the flame is the proper size.
  • Page 18: Gas Conversions

    All manuals and user guides at all-guides.com GAS CONVERSIONS Gas conversions from Natural gas to LP gas or from LP gas to To Convert Gas Pressure Regulator Natural gas must be done by a qualified installer. 1. Locate gas pressure regulator at the rear of the range. WARNING Explosion Hazard Use a new CSA International approved gas supply line.
  • Page 19: Natural Gas Conversion

    All manuals and user guides at all-guides.com 11. Complete installation. See “Make Gas Connection” and To Convert Surface Burners Electronic Ignition System” sections. Checking for proper cooktop burner flame is very important. 1. If installed, remove the burner grates. The small inner cone should have a very distinct blue flame 2.
  • Page 20 All manuals and user guides at all-guides.com 4. Apply masking tape to the end of a ⁹⁄₃₂" (7.0 mm) nut driver to 2. Unscrew the hex-shaped regulator cap from the regulator and remove the regulator pin. help hold the LP gas orifice spud in the nut driver while changing it.
  • Page 21: Moving The Range

    All manuals and user guides at all-guides.com Moving the Range For direct-wired ranges: WARNING WARNING Tip Over Hazard Electrical Shock Hazard A child or adult can tip the range and be killed. Disconnect power before servicing. Connect anti-tip bracket to rear range foot. Replace all parts and panels before operating.
  • Page 22: Sécurité De La Cuisinière

    All manuals and user guides at all-guides.com SÉCURITÉ DE LA CUISINIÈRE Votre sécurité et celle des autres est très importante. Nous donnons de nombreux messages de sécurité importants dans ce manuel et sur votre appareil ménager. Assurez-vous de toujours lire tous les messages de sécurité et de vous y conformer. Voici le symbole d’alerte de sécurité.
  • Page 23 All manuals and user guides at all-guides.com Dans l’État du Massachusetts, les instructions d’installation suivantes sont applicables : Les travaux d’installation et réparation doivent être exécutés par un plombier ou tuyauteur qualifié ou licencié, ou par le personnel qualifié d’une entreprise licenciée par l’État du Massachusetts. Si une vanne à...
  • Page 24: Exigences D'installation

    All manuals and user guides at all-guides.com EXIGENCES D’INSTALLATION Outils et composants Exigences d'emplacement Rassembler les outils et composants nécessaires avant IMPORTANT : Observer les dispositions de tous les codes et d’entreprendre l’installation. Lire et observer les instructions règlements en vigueur. Ne pas obstruer le flux de combustion et fournies avec chacun des outils de la liste ci-dessous.
  • Page 25 All manuals and user guides at all-guides.com Au Canada, l'installation de cette cuisinière doit satisfaire aux IMPORTANT : En cas d'installation d'une hotte ou d'un stipulations de la version la plus récente de la norme CAN/CSA- ensemble hotte/micro-ondes au-dessus de la cuisinière, suivre A240 ou des codes locaux en vigueur.
  • Page 26: Spécifications Électriques

    All manuals and user guides at all-guides.com REMARQUE : Distance minimale de séparation de 24" (61,0 cm) Cette cuisinière est dotée d’un cordon d’alimentation lorsque le fond d'un placard de bois ou de métal est protégé par (homologation CSA International) destiné à être branché sur une planche ignifugée d'au moins ¹⁄₄"...
  • Page 27 All manuals and user guides at all-guides.com Robinet d'arrêt nécessaire : Type de gaz La canalisation d'alimentation doit comporter un robinet d'arrêt manuel. Le robinet d'arrêt manuel doit être séparé de la cuisinière, mais doit se trouver dans la même pièce en un Gaz naturel : endroit où...
  • Page 28: Instructions D'installation

    All manuals and user guides at all-guides.com INSTRUCTIONS D'INSTALLATION REMARQUE : Pour replacer la cuisinière en position Déballage de la cuisinière verticale, placer un carton ou un panneau de fibres dur devant la cuisinière. À l’aide de deux personnes ou plus, relever la cuisinière et la placer sur le carton ou le panneau de AVERTISSEMENT fibres dur.
  • Page 29: Raccordement Au Gaz

    All manuals and user guides at all-guides.com 3. Déterminer et marquer l’emplacement du bord de la 5. À l'aide d'un tournevis Phillips, monter la bride cuisinière dans l'espace à découper. On peut installer la bride antibasculement sur le mur ou sur le plancher avec les deux de montage du côté...
  • Page 30: Vérification De L'emplacement De La Bride Antibasculement

    All manuals and user guides at all-guides.com 4. Le conduit d'alimentation en gaz doit être installé avec Faire glisser de nouveau la cuisinière de façon à ce que le pied arrière de la cuisinière se trouve sous la bride dégagement suffisant, tel qu’indiqué dans l'illustration antibasculement.
  • Page 31: Achever L'installation

    All manuals and user guides at all-guides.com Vérifier que chaque robinet d'arrêt est ouvert. Achever l'installation Vérifier que les chapeaux de brûleur sont correctement placés sur les bases de brûleur. 1. Vérifier que toutes les pièces sont maintenant installées. S’il reste une pièce, passer en revue les différentes étapes pour Répéter le processus de mise en marche.
  • Page 32: Conversions De Gaz

    All manuals and user guides at all-guides.com CONVERSIONS DE GAZ Les conversions pour changement de gaz naturel à gaz propane 2. Débrancher la cuisinière ou déconnecter la source de courant ou de gaz propane à gaz naturel doivent être effectuées par un électrique.
  • Page 33: Conversion Pour L'alimentation Au Gaz Naturel

    All manuals and user guides at all-guides.com 3. Emboîter la goupille sur le détendeur et l’enclencher 10 000 BTU Vert fermement en place. 14 000 BTU Rouge 114L 5. Remplacer le gicleur pour gaz naturel par le gicleur pour propane correct. Voir le “Tableau de sélection des gicleurs pour gaz propane”.
  • Page 34 All manuals and user guides at all-guides.com 3. À l’aide d’un tournevis Phillips, retirer la base du brûleur. Conversion du détendeur 1. Déterminer l’emplacement du détendeur à l’arrière de la cuisinière. A. Chapeau de brûleur A. Détendeur B. Ouverture du tube d’arrivée de gaz C.
  • Page 35: Déplacement De La Cuisinière

    All manuals and user guides at all-guides.com 11. Achever l’installation. Voir les sections “Raccordement au Faire glisser de nouveau la cuisinière de façon à ce que le pied arrière de la cuisinière se trouve sous la bride gaz” et “Système d’allumage électronique”. antibasculement.
  • Page 36 All manuals and user guides at all-guides.com W10162495A © 2008. 3/08 All rights reserved. Printed in U.S.A. Tous droits réservés. Imprimé aux É.-U.