WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 8 gauge copper wire.
Electrically ground cooktop.
Failure to follow these instructions can result in death,
fire, or electrical shock.
This cooktop is manufactured with a white (neutral) power supply
wire twisted together with a green (or bare) grounding wire
connected to the cooktop.
Home power supply cable and connectors are not provided.
See the "Electrical Connection Options" chart to complete
installation for your type of electrical connection.
Electrical Connection Options
If your home has:
And you will be
connecting to:
4-wire
A fused
disconnect or
circuit breaker
box
½"
(1.3 cm)
3-wire
A fused
disconnect or
circuit breaker
box
½"
(1.3 cm)
4-Wire Cable from Home Power Supply to 4-Wire Cable
to Cooktop
IMPORTANT: Use the 4-wire cable from home power supply in
the U.S. where local codes do not allow grounding through
neutral, New Branch circuit installations (1996 NEC), mobile
homes and recreational vehicles, new construction, and in
Canada.
A
B
C
D
A. Green (or bare) ground wires
B. White wires
C. Black wires
D. Cable from home power supply
10
Make Electrical Connection
Go to Section:
4-Wire Cable from
Power Supply
3-Wire Cable from
Power Supply
E
F
G
H
E. Plenum wiring box
F. Red wires
G. UL listed wire connector
H. UL listed or CSA approved
strain relief
1. Disconnect power.
2. Remove wiring box cover from the cooktop plenum.
3. Remove the appropriate knockout for the size of the home
power supply cable on the bottom side of the cooktop wiring
box. Use a UL listed or CSA approved strain relief to connect
home power supply cable to cooktop wiring box.
4. Connect the green (or bare) ground wire from the home
power supply to the green (or bare) ground wire in the plenum
wiring box using the UL listed wire connectors.
5. Connect the 2 black wires together using the UL listed wire
connectors.
6. Connect the 2 red wires together using the UL listed wire
connectors.
7. Connect the 2 white wires together the UL listed wire
connectors.
8. Tighten screws on the strain relief.
9. Install cooktop wiring box cover on plenum wiring box.
3-Wire Cable from Home Power Supply to 4-Wire Cable
to Cooktop - U.S. only
IMPORTANT: Use the 3-wire cable from power supply where
local codes permit connecting the frame-ground conductor to
the neutral (white) junction box wire.
A
B
C
D
E
A. Plenum wiring box
B. White wire and green (or bare)
wire (from cooktop)
C. Black wires
1. Disconnect power.
2. Remove wiring box cover from the cooktop plenum.
3. Remove the appropriate knockout for the size of the home
power supply cable on the bottom side of the cooktop wiring
box. Use a UL listed or CSA approved strain relief to connect
home power supply cable to cooktop wiring box.
4. Connect the green (or bare) ground wire and the white wire
from in the plenum wiring box to the white wire from the
home power supply cable using the UL listed wire
connectors.
5. Connect the 2 black wires together using the UL listed wire
connectors.
6. Connect the 2 red wires together using the UL listed wire
connectors.
7. Tighten screws on the strain relief.
8. Install cooktop wiring box cover on plenum wiring box.
F
G
D. Red wires
E. Cable from home power supply
F. UL listed wire connector
G. UL listed or CSA approved
strain relief