1
INSTALLATION
Instructions which must be followed by the drive and home automation professional installing the drive:
- Methods of wiring are given by national standards or IEC60364 standard.
- Cables which pass through a metal wall must be protected and isolated using a sheath or sleeve.
- The cable for the motor cannot be removed. If it is damaged, return the drive to the After-Sales department.
Recommendations: Keep a minimum distance of 20 cm between two T3.5 EHz DC motors. Keep a minimum
distance of 30 cm between T3.5 EHz DC motors and Hz transmitters. Simu recommends placing the connectors
between the end piece and flange, and fixing the cables inside the roller shutter box. The cables and connectors
must be protected from the roller shutter movement. A radio appliance using the same frequency (433,42MHz)
may deteriorate our product's performance (ex.: hi-fi radio headphones). Do not position the transmitter near
metal in order to avoid range losses.
Refer to instruction 5117585/5139459 for solar panel installation.
Refer to instruction 5136806/5139158 for battery installation. Recharge the battery before use with
the charger ref. 9020638.
i
The T3.5 EHz DC motor is compatible with all Simu Hz transmitters (12 transmitters (1 channel) max. for one
motor). Please refer to the corresponding instructions.
Drilling of the tube:
Mounting:
PLASTITE FXSN7/7X12 ZING JA.
2
END LIMIT ADJUSTMENT
If the installation includes several motors, only one motor should to be powered during this programming
procedure 2.1. It will eliminate interferences with the other motors during the procedure.
2.1- Learning mode:
1- Connect the 12V battery to the motor.
When using another power supply than Autosun 2 system battery
and solar panel, please refer to the technical booklet 5139543.
2- Then, connect the 12V solar panel to the motor. Go to next step.
3- Press simultaneously on the "UP" and "DOWN" buttons of the Hz
transmitter. The motor turns 0.5 second in one direction, then in the
other. This transmitter now commands the motor in unstable mode. Go
to step 2.2.
i
During the first three seconds of running during a Up or Down
movement, the motor will operate with slower speed to ease the limit
setting.
EN
2/8
A
ØB
L2
L1
29
Ø38,2
IP44
(5005970)
1,2
A
C
D
3Nm - 6Nm - 10Nm
1
40
ØB
A
ØB
C
Ø min.
(mm)
(mm)
(mm)
(mm)
37
433 4,2
8
4
2
9016635
=
2
3 >>
1
D
L1
L2
(mm)
(mm)
(mm)
5,5 457 470
3
1