FRONT PANEL
Wiring with an AFF04 display
SPL power
supply
Sensor
3 ) RJ45 opto mos relay output connector corresponding to alarm level exceeding.
GPO1
GPO2
Internal OPTO MOS wiring
CMD 2
CMD 1
Caution: Do not connect any computer to this jack, excess risk of damage to your
network adapter.
4 )
USB type B connector for firmware upgrade only.
5 )
RJ45 connector to ethernet (LAN)
AMIX
PS 12V
SPL25
SPL25 front panel
DC supply : 12 Volts 400 mA
GPO1
GPO2
1
+
SENSOR
-
V+
OPTO MOS 2
OPTO MOS 1
8
1
+
SENSOR
-
V+
OPTO MOS 2
OPTO MOS 1
8
1
2
3
V+
4
5
6
7
8
LAN
Connect a EIA/TIA 568B between SPL25 RJ45 socket
(GPO1/GPO2) and AFF04 RJ45 socket (GPO1/GPO2)
Connect the CAP65 sensor to SPL25.
Connect SPL25 to the provided supply .
Leds GPO1 and GPO2 display GPO1 and GPO2 state, and
allow to recover the equipment IP address. (see page 33)
Note :
Each OPTO can be considered as a relay and offers
all the advantages (alternative signals, no
polarization). Current limit is fixed at 200mA.
30
Sensor
AFF04
AFF04 rear panel
DC supply : 12 Volts 400 mA
GPO1
GPO2
Next
THRU
SPL25