Adjust the legs and tighten the fitting bolts (for models MSW-DRAIN CLEAN 2.3E (6351) |
MSW-POWER DRAIN CLEAN 2.3E (6359))
attach the protective pipe by inserting it into place (for model MSW-POWER DRAIN CLEAN
4.6E (6360)
and pull out an appropriate length of the selected coil. The method of connecting the coil can be found
below. When the coil is ready, attach an appropriate tip with the power supply turned off.
Or in the case of the model MSW-POWER DRAIN CLEAN 2.3E (6359) use the included tube instead
of the pipe.
3.
Next, insert the coil prepared in advance into the opening of the device. Insert the coil in such a way
as to put the end of the coil without the tip into the opening located at the front of the device –
opposite the power cable (in the model MSW-POWER DRAIN CLEAN 4.6E (6360), the coil should
be inside the protective pipe). Leave about 50cm of the coil in front of the device. When the device is
ready for clearing, connect it to the mains.
In the case of using the tube instead of the coil in the MSW-POWER DRAIN CLEAN 2.3E (6359)
model, insert the narrow end of the tube into the rear of the device (on the power cable side). In
order to do so, lift the locking pin located on the top of the enclosure, insert the tube and release the
pin. Next, check if the tube is sufficiently stable and secured against falling out of the machine. Pull out
enough coil from the tube for the coil to protrude from the front of the device after attaching the
pipe.
4.
In order to start clearing, place the device about 50cm from the place of inserting the coil, insert the
coil into the opening in such a way as to prevent the coil from twisting and curling when the motor is
on and put the direction switch located at the engine in the "FOR" position – the engine of the device
is active, but the torque is not transmitted to the coil until the lever is put in the lower position. Next,
insert an appropriate length of the coil (pulling it out of the device) into the opening of the cleared
pipe. Use protective gloves! When the coil is in the right place, put the lever in the lower position start
clearing. In order to insert consecutive sections of the coil into the opening, put the lever in the upper
position, thus stopping the coil, then, wearing protective gloves, push another section in and put the
lever in the lower position again. Caution! When standing near the coil, remember about the existing
torsional torque. The coil can move independently at any time, even when the drive is off.
In the case of using a tube instead of a coil in the MSW-POWER DRAIN CLEAN 2.3E (6359) model,
place the device about 50cm from the place of inserting the coil and put the direction switch located
at the motor in the "FOR" position and put the lever in the lower position. Next, insert the coil into
the opening is such a way that prevents it from being twisted or curled when the device is on and start
clearing by putting the lever in the lower position.
The model MSW-POWER DRAIN CLEAN 2.3E (6359) is fitted with a special lever lock. To
engage it, put the lever in the lower position and lock it with a handle (located next to the tube fitting
place) by turning it clockwise. Thanks to this handle, the device can be conveniently carried using the
lever. In order to disengage the lock, press the lever down and turn the handle counter-clockwise.
You should always be prepared to stop the device in case of emergency
16
5.
In order to pull the coil out, it is neccesary to change its rotation direction. In order to do so, put the
lever in the upper position, put the switch in the "OFF" position, wait for the motor to come to a full
stop, then set the direction to "REV" and put the lever in the lower position again. When pulling the
coil out, it must be under constant supervision. In order to remove the tube in the MSW-POWER
DRAIN CLEAN 2.3E (6359) model, lift the pin and pull the tube out.
6.
After completing the clearing and removing the coil, put the lever in the upper position, set the
switch to „OFF" and disconnect the device from the mains. Before winding the coil, clean the device
thoroughly.
THE METHOD OF CONNECTING/DISCONNECTING THE COIL AND THE TIPS - APPLICABLE TO
MODELS MSW-DRAIN CLEAN 2.3E (6351) | MSW-POWER DRAIN CLEAN 2.3E (6359) | MSW-POWER
DRAIN CLEAN 4.6E (6360)
IX. TRANSPORTATION AND STORAGE
Shaking, crashing and turning upside down of the device should be prevented when transporting it. Store it
in a properly ventilated location with dry air and without any corrosive gas.
X. CLEANING AND MAINTENANCE
Disconnect from electricity when cleaning equipment.
Use cleaner without corrosive substances to clean surface.
Dry all parts well after cleaning before the device is used again.
Store the unit in a dry, cool location, free from moisture and direct exposure to sunlight.
Never spray the device with water jets.
After finishing work, leave the device working on idle for about 2 minutes. Put a small amount of oil
into the oil holes – depending on the size of the machine.
All the working elements such as the coil, outlet nozzle and tube should be kept clean. The coil should
be properly lubricated (oiled).
XI. REGULAR CONTROL OF THE DEVICE
Check the machine regularly for signs of damage. If the machine is damaged, please stop using it immediately
and contact your customer service to solve the problem.
What to do in case of a problem?
Please contact your customer service and prepare following information:
Invoice number and serial number (the latter is to be found on the technical plate on the machine).
If relevant, a picture of the damaged, broken or defective part.
It will be easier for your customer service clerk to determine the source of the problem if you
give a detailed and precise description of the matter. The more detailed your information, the better
customer service will be able to solve your problem rapidly and efficiently!
CAUTION: Never open the machine without the authorization of your customer service. This can lead to
a loss of warranty!
Rev. 16.08.2017
Rev. 16.08.2017
In order to connect the end of the coil with another end / tip, insert the matching part of
the spiral as shown in the illustration. Next, check if the joint is solid and if the pin located
inside is visible. This is the only way of connecting the coils, so it must be done properly.
The manufacturer does not provide for the possibility of joining different diameter tips/
coils.
In order to disconnect the elements, insert the wrench provided with the device into the
hole located near the middle of the joint in such a way that the wedge profiled on the
wrench pushed the locking pin inside. Next, pull both ends apart holding the coil and/or
the tip with both hands. When disconnecting, the wrench must be inside the hole.