5. Place the base in the correct position on the floor plate (if
any). Level the product using the 4 adjustment screws (Fig. 19 A).
6. Attach the base to the burn chamber using the 4 screws (M8
x 30 mm) from the bag of screws (Fig. 19 B).
7. Carefully raise the product with the help of another person.
8. Adjust the glass door, if necessary, with the screws as shown
in Fig. 17 C. There must be an even gap between the door and
the base to allow the door to hang straight.
9. Install the side glass panels by positioning them in the lower
glass clips (Fig. 20 A). Lift up the upper clips and press them
down onto the side glass. Make sure there is an even gap
between the side glass and the side plate at both the front
and back. Tighten the front screw for the side glass (Fig. 18 B).
The back screw (Fig. 18 C) should be loosened just sufficiently
to allow the glass clip to be raised without removing the screw
(this makes it easier if replacing the glass later on).
10. Pull the flex hose (if any) through a hole in the floor or rear of
the base (Fig. 18 A) and attach it to the outlet using a hose clip.
11. NB! Make sure the hose is long enough to make it unnecessary
to have any joints.
12. Replace the rear plate (Fig. 18 D).
13. The base area must be protected from heat radiation from
the product with the aid of the accompanying heat shield
(fig. 8A). Fasten this with the 2 screws as shown in fig. 8B.
Jøtul F 379 - with three legs
NB! If connecting the flex hose through a hole in the floor, do not
knock out the removable cover plates (fig. 29 A).
1. If connecting a flex hose (Ø 100 mm) for external air supply
to the external air vent (fig. 4 C) beneath the burn chamber,
first drill a hole (fig. 29 A) in the removable cover plates before
they are knocked out. NB! Place the parts on a suitable surface
before the cover plates are knocked out.
2. The accompanying heat shield should be used to protect the
base from the heat radiating from the product (fig. 30 A).
Secure this first with a screw (fig. 30 B).
3. Secure the brace (fig. 30 C) loosely into place with a screw
(fig. 30 D).
4. Attach the base to the burn chamber using the 4 screws (M8
x 30 mm) from the bag of screws (fig. 4 A).
5. Screw the legs together at the back edge using 2 screws that
are in the screw holes (fig. 30 E).
6. Secure the brace (fig. 30 C) into place with a screw (fig. 30 F)
and nut at both ends.
7. With the help of another person, carefully raise the product.
8. Level the product using the 4 adjustment screws (fig. 30 G).
9. If the legs are not properly aligned, loosen the screws (fig. 30 F)
on each side. Adjust the legs and tighten the screws again.
10. Tighten the screw (fig. 30 D).
11. Pull the flex hose through the hole and attach it to the outlet
using a hose clip. NB! Make sure the hose is long enough so
that joints are not necessary.
12. Place the cover (fig. 31 A) into place. Make sure that the pin
(protrusion) B is facing down.
Products with convection kits
Jøtul F 371, Jøtul F 372, Jøtul F 373, Jøtul F 374, Jøtul F 375, Jøtul F
376 and Jøtul F 379 are also supplied with convection kits.
These products have the designations Jøtul F 371 CV, Jøtul F 372 CV,
Jøtul F 373 CV, Jøtul F 374 CV, Jøtul F 375 CV, Jøtul F 376 CV and
Jøtul F 379 CV. Cat. no. 351172, BP. Cat. no. 351173, GP.
30
3.3 Chimneys and flue pipes
The fireplace can be connected to a chimney and flue
pipe approved for solid fuel fired appliances with flue gas
temperatures specified in «2.0 Technical data".
The chimney's cross-section must be at least as big as the
flue pipe's cross-section. See «2.0 Technical data» when
calculating the correct chimney cross-section.
Several solid fuel fired appliances can be connected to the
same chimney if the chimney's cross-section is sufficient.
Connection to the chimney must be carried out in accordance with
the installation instructions from the supplier of the chimney.
Before making a hole in the chimney the fireplace should be
test-mounted in order to correctly mark the position of the
fireplace and the hole in the chimney. See fig. 1 for minimum
dimensions.
Ensure that the flue pipe is inclined all the way up to the chimney.
Use a flue pipe bend with a sweeping hatch that allows it to
be swept.
Be aware of the fact that it is particularly important that
connections have a certain flexibility in order to prevent
movement in the installation leading to cracks.
Chimney draught; See «2.0 Technical data». If the draught is
too strong you can install and operate a flue damper to control
the draught.
Assembly of flue pipe with top outlet (fig. 21)
The product is supplied from the factory with the smoke outlet
mounted for top outlet.
1. Put the top plate (fig. 21C) on the product.
2. Obtain assistance in lifting the top grate (fig. 21A) and holding
it up while the flue is fastened.
3. Thread the flue pipe through the grate of the top plate and
place it on the smoke outlet of the top outlet.
4. Tighten well with gasket.
Assembly of flue pipe with rear outlet
(fig. 1, 3, 21 and 22)
The product is supplied from the factory with the smoke
outlet mounted for top outlet. If you want a rear outlet, do the
following:
1. Place the product in correct position (fig. 1).
2. When changing to rear outlet, the smoke outlet (fig. 3B) is
unscrewed from the top outlet.
3. Unscrew the cover for the rear outlet from the inside of the
burn chamber (fig. 3A).
4. Place the gasket on the end of the flue pipe (fig. 22 A).
5. Mount the smoke outlet (fig. 22 B) on the end of the flue pipe
that is fitted with the gasket.
6. Mount the flue pipe and smoke outlet from the inside of the burn
chamber and attach the smoke outlet using M8x30 mm screws.
N.B. If the flue pipe is longer than 350 mm it has to be assembled
into the smoke outlet from the outside of the product.
7. Fasten the cover to the top outlet (fig. 21) with the screws
that fastened the smoke outlet.
N.B. It is important that the joints/flue pipes are completely
sealed. Air leaks can prevent the flue pipe from functioning
properly.