The heating curve is based on an outside temperature of 20°C. When the desired room
i
temperature is increased, the heating curve shifts upwards. The degree of increase is
determined using the RT effect function.
RT effect: factor influencing the shift in the heating curve.
•
Heat limit day: outside temperature above which the central heating is switched off during the
•
day. The day temperature limit is relevant when the desired room temperature is higher than the
night temperature that has been set via Menu > Program > Night temp.
•
Heat limit night: outside temperature above which the central heating is switched off during the
night. The night temperature limit is relevant when the desired room temperature is the same as
or lower than the night temperature that has been set via Menu > Program > Night temp..
EN
37