External dosing devices
17.2 Electrical connection
When connecting an external dosing device to the control board, there must be no short circuit.
The control board can be destroyed by a short circuit.
Connect external dosing devices only with their own fuse protection.
Caution
IMPORTANT
Maximum current drain at the transfer strip: 0.5 A.
Terminal
Signal description
N
Neutral/phase 2
L1
Phase 1/continuous voltage
Terminal
Voltage present
While machine fills
Parallel to the solenoid valve (O7)
DETERGENT
 While machine fills
 During the rinse
WASH
Parallel to the wash pump
Parallel to the rinse pump (O12)
Parallel to the solenoid valve (O7)
RINSE
 While machine fills
 During the rinse
a) hood/door closed
b) minimum water level in the tank
c) not during the self-cleaning programme
d) not while the machine is being filled
e) not during the descaling and basic cleaning programme
80
 Connect the external dosing device to the 5-pin plug.
 Programming the transfer strip ( 17.3).
Condition
a), b)
a)
a)
a)
a)
Restriction
c)
c), d), e)
c), d), e)
c)