Installing the machine
15 Installing the machine
The installation site must be frost-resistant to prevent the water supply systems from freezing.
Install the machine horizontally using a spirit level.
Adjust the base unevenness using the height-adjustable machine feet.
16 Connecting the machine
The machine and any other relevant additional devices must be connected in adherence to
local standards and regulations by an electrical company authorised by the relevant electricity
supplier.
Warning
16.1 Location of connections on the machine
PTD 701
460
EZ
DOS
TWw
Rear view
EZ
Entry for mains cable
DOS Port for hoses (detergent / rinse aid) and cables
TWw Inlet water connection (G ¾", external thread)
Connection for on-site equipotential bonding system
P
A
Waste water connection; drain pump installed
16.2 Accessories
1
G 3/4"
1500 mm
1
Flexible inlet hose
2
Flexible drain hose
3
Water inlet filter
74
PTD 702, PTD 703, PTD 704
P
A
DOS
TWw
2
G 3/4"
1500 mm
connect to point TWw
connect to point A
install in accordance with chapter 16.5
600
EZ
62
P
A
Right view
3
G 3/4"
G 3/4"