Special Features; Safety Instructions; General Warnings; Intended Use - ubbink Smartmax Fi Série Mode D'emploi

Table des Matières

Publicité

1 Operating manual for Smartmax® Fi filter pumps
Ubbink Smartmax® filter pumps are high quality products that are based on state-of-the-art technology. The pumps are equipped with a frugal, extremely efficient and very
reliable motor system with adaptive frequency technology and a ceramic drive shaft. Smartmax® Fi pumps are specially suited for use as filter pumps.
Instructions for the use of this operating manual
Before using the device for the first time, please read this manual carefully and familiarise yourself with the device. For the proper and safe use of this device, please ensure that you
observe the safety instructions. Please keep this operating manual in a safe place! Please pass on this manual on change of ownership. All work performed with this device must be in
accordance with this manual.

Special features

Smartmax® Fi pumps have a number of special features that distinguish them from other pond pumps.
HEP – (high efficiency pump)
A robust and powerful pump with an extremely low power consumption, suitable for continuous service.
AFM – (adaptive frequency motor)
Top performance – and nevertheless extremely quiet.
NSS – (no sponge system)
Low maintenance due to a specially shaped housing with precisely tailored inlet slots.
TPS – (thermal protection system)
Additional protection against overheating through the integral thermostatic switch.
CST – (ceramic shaft technology)
Enhanced efficiency through the low-friction and low-noise motor operation due to the high quality drive shaft manufactured from technical ceramics.

Safety instructions

This device has been manufactured in accordance with the latest technology and current safety regulations. Nevertheless, the device can cause injury or damage to people and
property if the device is not used for its intended purpose or if the safety instructions are ignored.
• The power supply must must be in accordance with the product specifications. Do not switch on the device if the power supply does not comply with the specified regulations (VDE
0100-702)! You can obtain further information from your local certified electrician.
• The power supply circuit must be protected with a residual current device (FI or RCD) with a maximum residual current rating of 30 mA.
• The power supply for the device must be connected more than 3.5 m away from the pond.
• Always disconnect the power supply before working on the device (installation, maintenance etc.) or before you put your hand into the water!
• The device must not be operated when people are are in the water!
• It is not permitted to open the device or any of its parts except where expressly indicated in this operating manual. The same also applies to technical modifications to the device.
• The power plug and all connections must be kept dry at all times. Make sure the connecting cable is mechanically protected to prevent possible damage.
• The device must not be operated without water as this may cause irreparable damage.
• This device is suitable for pumping water with a minimum temperature of 10°C up to a maximum of 35°C.
• Do not operate devices that are obviously damaged! - The power cable cannot be replaced. - If the power cable is damaged, the device must be disposed of in the proper manner.
• Never use the cable to carry the device, and never pull the device out of the pond by the cable.
• Never remove the plug by cutting through the cable, and never shorten the cable. Failure to comply with these operating instructions will invalidate your warranty!
• This device may be used by children from the age of eight years upwards and by people with physical, sensory or mental disabilities or lacking suitable knowledge and experience,
if they are supervised or have been instructed in the safe use of the device and are aware of the resulting hazards. Children must not play with the device. Cleaning and user
maintenance must not be carried out by unsupervised children.

General warnings

Packaging parts can be dangerous (e.g. plastic bags) these must be therefore stored out of the reach of children and pets.

Intended use

The pumps of the Smartmax® range work with frugal, reliable and powerful motors with adaptive frequency technology that guarantee a delivery head of 2.2 m (1500 Fi), 3.0m (2500
Fi), 3.6 m (5000 Fi), 4.6 m (7500 Fi) and 6.0 m (10000 Fi).
All pumps are specially suited for use as filter pumps in combination with filter systems such as Ubbink BioPressure II. FiltraClear, Filtramax or BioClear.
The pumps of the Smartmax® Fi series are not self-priming pumps. It is therefore important that these are positioned beneath the water level.
Note: It is possible that lubricant can leak out while the pump is operating; this can result in pollution of the water.

Publicité

Table des Matières
loading

Table des Matières