Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 145
Operating Instructions SATAminijet 3000 B HVLP, minijet 3000 B T HVLP
• Check if locking screw has been firmly tightened! Air micrometer could
shoot out from the spray gun uncontrolled!
9.6. Replace spindle of round/flat spray control
steps: [11-1], [11-2], [11-3]
The spindle has to be replaced when air leaks from the spray control or
when the spray control does not work.

10. Trouble-shooting

Malfunction
Fluttering/Spitting
spray fan or air bub-
bles appearing in the
gravity cup
Air bubbles appearing
in the gravity cup
Warning!
Cause
Fluid tip has not been
properly tightened
Air distribution ring is
damaged or clogged.
Loose air cap
Gap between air cap
and fluid tip ("air cir-
cuit") is clogged
Nozzle set is clogged
or damaged
Not enough paint ma-
terial in the gravity cup
Defective paint needle
sealing
Corrective Action
Tighten fluid tip [2-1]
with universal spanner
Replace air distribution
ring which will be dam-
aged during extraction
Tighten air cap [2-2]
by hand
Clean air circuit, ob-
serve chapter 8
Clean the nozzle set,
chapter 8, or replace,
chapter 9.1
Refill gravity cup [1-6]
Replace the paint nee-
dle sealing, chapter
9.3
EN
107

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Minijet 3000 b t hvlpSataminijet 3000 b hvlp

Table des Matières