Direct voltage (V/DC)
Range
600.0 mV
6.000 V
60.00 V
600.0 V
1000 V
1000 V overload protection; Impedance: >10 MΩ
Alternating voltage V/AC True RMS
Range
6.000 V
60.00 V
600.0 V
1000 V
Specified measurement range: 10 - 100% of the measurement range, sine wave
1000 V overload protection; Impedance: >9 MΩ
Accuracy of PEAK function: ±10% of the reading, peak value recording time: 1 ms
Voltage V/AC + DC True RMS
Range
6.000 V
60.00 V
600.0 V
1000 V
Frequency range: 50 Hz - 1 kHz; Overload protection: 1000 V; Impedance: >10 MΩ
Direct current (A/DC)
Range
600.0 µA
6000 µA
60.00 mA
600.0 mA
10.00 A
Overload protection: 1000 V
Fuse: µA/mA = ceramic high-performance fuse FF 800 mA/1000 V
10 A = Ceramic high-performance fuse FF 10 A/1000 V
≤6 A = Continuous measurement, >6 A = max. 10 s at intervals of 15 minutes
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 µA
1 µA
0.01 mA
0.1 mA
0.01 A
Accuracy
±(0.09% + 5)
±(0.2% + 5)
Accuracy
50 – 60 Hz
61 Hz – 1 kHz
±(0.8% + 5)
±(2.4% + 5)
Accuracy
±(2.4% + 20)
Accuracy
±(0.9% + 5)
±(0.9% + 8)
±(1.5% + 8)