Fig. 3 "H" class machine
1. Motor head incl. handle
2. On / Off button
3. Exhaust filter cover
4. ULPA U 15 exhaust filter
5. Top container
6. Vacuum Gauge / Manometer
8. "H" class HEPA H 13 filter
9. Dust container
10. Blind cover for inlet
11. Stainless steel clamps
12. Stainless steel clamps
Fig. 4 "Safe Pack" machine
1. Motor head incl. handle
2. On / Off button
3. Exhaust filter cover
4. ULPA U 15 exhaust filter
5. Top container
7. "Safe pack" unit
8. HEPA H 13 filter fixed inside safe pack unit
9. Stainless steel clamps
10. Trolley
4 - Safety
Attention!!
Check that all clamps are correctly positioned and working
correctly before starting and using the machine.
Never tamper with the safety devices.
Always check that the protection and safety devices are-
mounted and working at the beginning of each work shift or
before using the machine. If this is not the case, switch off the
vacuum and report fault.
The vacuum has been manufactured with particular attention
to the operator's safety. Comply with the maintenance and
technical assistance procedures and information given in this
manual. Never use compressed air to clean the machine or
itscomponents. Never open the waste container whilst the
vacuum is operating. Before beginning electrical connection,
check that the voltage and frequency values are those indi-
cated on the data plate of the machine.
Connect the machine to the electricity main with an efficient
ground circuit.
Only authorized personnel must be allowed to work on the
electrical part of the machine and this must always be discon-
nected from the electricity main.
Never move the vacuum by pulling the power cable. Thismay
damage the vacuum itself and the operator may be exposed
to electric shocks.
5 - Testing, delivery, installation
5.1 - Testing
The machine has been tested in our plantin order to ensure
that it operates correctly. Tests on the suction values are car-
ried out during this phase. This ensures that the vacuum has
been optimised according to the job for which it was designed.
5.2 - Delivery and handling
The machine is delivered, in a cardboard box.
When receiving the machine check for concealed damage.
If damage is discovered, immediately file a complaint with the
carrier.
The machine can be stored at temperatures between 0 and
50°C, and 65% relative humidity. Before storage the machine
02/2013
must always be cleaned in accordance with the instructions.
The machine can be operated in the temperature range -5 to+
50 °C and 65 % relative humidity.
The delivery packaging should be disposed of in accordance-
with the relevant statutory regulations.
Dispose of a machine, which is no longer usable, inaccor-
dance with the relevant statutory regulations.
Only use approved commercially available, non-combustible
and non-toxic solvents for the purpose of cleaning the machi-
ne Stainless steel body parts and accessories can be cleaned
in an autoclave at 121°C
5.3 - Certificate of guarantee
The certificate of guarantee is packed with the vacuum.
5.4 - Installing the vacuum
Attention!!
The user shall be responsible for ensuring that installati-
oncomplies with the local statutory regulations.
A qualified technician, who has read and understood the
instructions herein, must install the equipment.
The floor on which the vacuum must operate should be level,
flat and smooth. If the vacuum is to work in a fixed position,
allow ample space all round in order to ensure freedom of
movement and make sure that the maintenance staff to ope-
rate with ease.
5.5 - Connecting to the electricity main
Attention!!
Check that the voltage and frequency values of the electricity
main correspond to the values indicated on the data plate
described in paragraph 3.1 (data plate).
Specialised personnel must carry out all installation andmain-
tenance work on electrical parts.
Connect the equipment to an efficient earth.
Ensure that the electrical supply matches the machine rating
plate.
6 - Controls (Fig. 5)
1. On / Off button
2. Vacuum Gauge / Manometer ("H" class machine only)
7 - Starting and stopping
7.1 - Caution
Attention!!
Unauthorized personnel are forbidden to use the vacuum.
7.2 - Starting / Stopping
Check that the machine has been effectively connected to the
electricity main.
In particular, check that the main voltage and frequency
values correspond to those indicated on the data plate. (see
fig. 1).
Fit the accessories to the suction inlet.
Use the stainless steel clamp to fix the hose to the inlet.
Place the vacuum near the place of use, then lock the wheels
by pressing levers downwards.
The machine is switched ON or OFF by pressing the grey
button on the upper part of the motor.
8 - Using the vacuum (fig. 7)
8.1 - Correct use of the vacuum
Before using the machine, connect the suction pipe to the
inlet as indicated in paragraph 7.2.
Keep long suction pipes as straight as possible.
Do not allow them to bend or twist as this will cause exces-
sive wear and clogging.
43