Installation Instructions - Bradley On-Site S19-921 Manuel D'utilisation

Masquer les pouces Voir aussi pour On-Site S19-921:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

S19-921, S19-921H, S19-921HR
Installation
Step 1: Mount eyewash pedestal to wall
(optional)
CAUTION: Eyewash station weighs 60 lbs when
filled to capacity. Assistance from another
individual may be required to safely install the unit.
Mounting bracket screws and wall anchors must be
strong enough to support the filled unit.
1. To mount the pedestal to the wall, follow the procedure outlined
below:
• Secure the mounting bracket to the wall with screws and wall
anchors (provided by installer).
OPTIONAL HEATER JACKET: Place the pedestal into the
heater jacket. Insert the tube from the drain hole at the
bottom of the pedestal through the hole in the back of the
heater jacket. Drain hole location is shown on page 5.
2. Attach the pedestal to the mounting bracket at the handles on
the back of the unit.
3. Check condition of gasket; ensure clamps are out of the way.
Check location of heater pad and routing of its power cable.
NOTE: When mounting the eyewash unit to the mounting bracket,
make sure the unit is level and the sprayheads are at a height
of 33-45" from the floor and situated at least 6" from the wall or
nearest obstruction (ANSI Z358.1-2004).
Step 2: Fill and mount tank
1. Pour clean, potable room temperature water into the tank;
continue pouring until the tank is 1/3 to 1/2 full.
2. Pour entire contents of the water preservative bottle (supplied)
into the eyewash tank.
3. Add clean, potable room temperature water to the tank until the
water level reaches the fill line.
4. Insert one liner into the cap (with hole) and attach the cap to the
top of the tank.
• Check location of heating pad and thermostat on tank as
shown in the illustration.
NOTE FOR TANK INSTALLATION: To ensure proper installation, the
tank should be placed on the pedestal from the front of the unit.
5. Invert the tank and place it on top of the pedestal as shown on
page 5. The pierce on the pedestal will puncture a hole in the
cap liner and allow solution to flow.
6. Raise the arm to snap fit in an upright position. A slight
adjustment to the position of the tank may be required for proper
level placement of the tank on the pedestal.
• Check to make sure jacket is not pinched under the tank and
for proper routing of all cables.
7. Secure the tank to the pedestal using the side tank clamps.
Make sure the latches are pulled down tight to the pedestal (see
page 5).
8. OPTIONAL HEATER JACKET: Insert the 5-pin connector from
the tank heater assembly into the mating socket on the junction
box and screw tight. Slide the heater jacket up to cover the tank
and secure the jacket with the hook-and-loop fasteners. Slide
the arm into pocket of the jacket flap.
NOTE: After the tank is mounted to the pedestal, minor spillage
could occur. Allow the fluid to stabilize completely before inspecting
the unit for leaks.
4
4/10/09
33"
(838mm)
to 45"
(1143mm)
Cap with Hole
Liner
(insert into cap before
attaching cap to tank)
Heater Pad
(S19-921H and
S19-921HR only)
Tank
Bradley Corporation • 215-1546 Rev. E; ECM 09-05-0003
Installation
(1133mm)
to 56
(1438mm)
Turn cap to close
Gasket
(S19-921H and
S19-921HR only)
Thermostat
(S19-921H and
S19-921HR only)
44
5
"
8
"
5
8

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

On-site s19-921hOn-site s19-921hr

Table des Matières