After establishing the parameter to be set, use the following conversion tables to understand the value being set, ac-
cording to the blinking of the LEDs. OFF means LED off, ON means LED on, whereas ON BL means LED blinking.
Red
OFF
ON BL
OFF
ON BL
OFF
ON BL
OFF
ON BL
Red
OFF
ON BL
Red
OFF
ON BL
OFF
ON BL
OFF
ON BL
OFF
ON BL
Red
OFF
ON BL
Red
OFF
ON BL
Red
OFF
ON BL
OFF
Red
OFF
ON BL
Red
OFF
ON BL
32
Green
Yellow
Max. heating power
OFF
OFF
00-11%
OFF
OFF
11-23%
OFF
ON BL
23-36%
OFF
ON BL
36-49%
ON BL
OFF
49-61%
ON BL
OFF
61-74%
ON BL
ON BL
74-85%
ON BL
ON BL
85-100%
Green
Yellow
Gas type selection
OFF
OFF
Natural gas
OFF
OFF
LPG
Green
Yellow
Lighting power
OFF
OFF
00-06%
OFF
OFF
06-13%
OFF
ON BL
13-21%
OFF
ON BL
21-29%
ON BL
OFF
29-36%
ON BL
OFF
36-44%
ON BL
ON BL
44-51%
ON BL
ON BL
51-60%
Green
Yellow
Heating idle time
OFF
OFF
00 minutes
OFF
OFF
2.5 minutes
Green
Yellow
Pump post-circulation
OFF
OFF
00 minutes
OFF
OFF
2.5 minutes
Green
Yellow
Heating max. setpoint
OFF
OFF
30°C
OFF
OFF
40°C
OFF
ON BL
85°C
Green
Yellow
Hot water max. setpoint
OFF
OFF
55°C
OFF
OFF
65°C
Green
Yellow
Heating sensor selection
OFF
OFF
Double sensor
OFF
OFF
Safety Therm. + Sensor
Cod. 3540D952 - 11/2008 (Rev. 00)
Taura 24 MCS