CNTR 20
Dimensions (mm): 133,2 x 154,2 x 44
Maximum number of outputs: up to 20 of which
- Number of proportional outputs: 1 (by losing 2)
- Number of digital inputs: up to 8 (losing outputs)
Maximum current available for each channel: 5A
Maximum total deliverable current: 20A
Main connector: FCI SICMA 24 Header pin
Communication interface: CANBUS (optional)
4-bit CANBUS addressing (up to 16 supported nodes)
Internal antenna
Receiver category (EN 300-221-1): 2
CNTR 32
Dimensions (mm): 185 x 156,5 x 41
Number of outputs: up to 32
Number of proportional outputs: up to 1
Number of digital inputs: up to 4
Maximum current available for each channel: 5A
Maximum total deliverable current: 20A
Main connector: FCI SICMA 56 Header pin
82
Communication interface: CANBUS (optional)
4-bit CANBUS addressing (up to 16 supported nodes)
External antenna
Receiver category (EN 300-221-1): 2
INSTALLATION
In order to ensure correct operation, the following rules must be respected:
· Installation must be performed by qualified personnel.
· Position the receiver vertically (with the cable outlet facing downwards)
and in an accessible way.
In order not to compromise reception, the CONTROLLER must not be shielded
from ferrous masses (e.g. protective casing).
CNTR 4
DIMENSIONS
(mm)