INSTRUCTIONS
The operativity of the system is identical for both EASY and TREND
handhelds, except for the "TREND wit PAGE CHANGE", for which there is a
specific procedure.
SWITCHING ON THE SYSTEM
1. Power the CONTROLLER already paired with the handheld (see PAIRING
page 85 in case of re-coding).
2. Wait a few seconds (system self-diagnosing).
3. Press START on handheld for at least 2 seconds to enable the CONTROLLER
at receiving commands; this also activates the EMERGENCY OUTPUT (EO)
which remains active for two minutes in the standard configuration, after
which it is deactivated (unless in the meantime any command is given).
To reactivate the EO, press START again.
4. Press the desired key on the handheld to operate the corresponding
output on the CONTROLLER;
example: KEY 1 => OUT 1 + MASTER OUTPUT (MO).
5. Press STOP to inhibit the reception of commands.
In this condition all commands are reset.
To reset the system, press START again for at least 2 seconds.
TREND WITH PAGE CHANGE
1. Power the CONTROLLER already paired with the handheld. Wait a few
seconds (system self-diagnosing).
2. Press START and key #1 on the handheld simultaneously to enable keys
from 1 to 14 (1st page), or START and key #2 simultaneously to enable
keys 15 to 28 (2nd page). The EMERGENCY OUTPUT (EO) is activated and will
remain active for 2 minutes after the last command received, after which it
will deactivate. To re-enable the EO, press START + key #1 or START + key
#2 for two seconds.
3. Press the desired button on the handheld to operate the corresponding
output on the CONTROLLER.
Example (1st page): KEY 1 => OUT 1 + MASTER OUTPUT.
Example (2nd page): KEY 1 => OUT 15 + MASTER OUTPUT.
4. Press STOP to inhibit the reception of commands. In this condition all the
commands are reset.
To reset the system, press START + 1 or START + 2 again for two seconds.
By pressing the START button only, the system will not
manage any outputs. It is therefore always necessary to
select the page where you want to operate.
77