Gauging Tape
Measurements
GC
GC Module
GC Module Assembly
GCM
GCM
GCN
GCNM
GDF
Gj
GND
GOST
GPA 2145-03
GPA 2172-96
GPM
GPS 2261
GPV
GPV
GRD
Gross Heating Value
2103971-001 – rev. AB
This refers to a manual method of measuring the level of a liquid in a
tank. These measurements may be used to calibrate float levels.
See Gas Chromatograph.
The NGC8200's GC module is comprised of three parts: columns,
chromatographic valve and GC module circuit board. The valve controls
the flow of gas within the system. The columns perform the separation
of the gas into component parts for analysis. The GC module circuit
board contains the sensors for the carrier pressure regulators, the
sample pressure sensor and the thermal conductivity detectors (TCD's)
which detect the different gas components as they leave the GC
columns. It also contains an EEPROM or FLASH memory for storage of
calibration and characterization information of the module and its
sensors.
The GC Module is comprised of 3 parts; Columns, Valves and
Electronic Interface. The Valves control flow of gas within the system.
The Columns perform the separation of the gas into component parts
for analysis. The Electronic Interface contains pressure and
temperature sensors to monitor and detect the different gas
components as they leave the GC Columns.
See Gas Chromatograph Module
See Gas Chromatograph Module Coefficient.
Gravity, Carbon Dioxide and Nitrogen compounds. Used in NX-19 GCN
Supercompressibility Factor.
Gravity, Carbon Dioxide, Nitrogen and Methane compounds. Used in
NX-19 GCNM Supercompressibility Factor.
Gasde of France
An abbreviation for gigajoule, equivalent to one thousand mega joules
or one billion joules.
See Ground.
Russian Government Standards for Importation.
Gas Processors Association Physical Constants for Paraffin
Hydrocarbons and other Components of Natural Gas
Gas Processors Association Calculation of Gross Heating Value,
Relative Density and Compressibility of Natural Gas Mixtures from
Compositional Analysis.
Gallons of liquid per thousand cubic feet.
See Gas Processors Standard 2261.
Gauge Port Vent. Refers to the NGC8200 Port designed to equalize the
pressure inside of the explosion-proof enclosure.
Gauge Port Valve (located on NGC8200 series Feed-Through
Assembly).
See Ground.
The heating value measured in a calorimeter when the water produced
during the combustion process is condensed to a liquid state. The heat
of condensation of the water is included in the total measured heat.