CONNECTING THE FEEDER CABLE
To connect the feeder cable to the cooker
it is necessary to:
– Remove the 6 screws that hold shield
A behind the cooker.
– Open completely the cable clamp D.
– Position the U bolts onto terminal block
B (fig. 10.1) according to the diagram
in fig. 10.2 and fig. 10.3.
– Insert the feeder cable into the cable
save P. The supply cable must be of a
suitable size for the current require-
ments of the appliance; see the
section "Feeder cable section".
– Connect the phase and earth cables to
terminal B according to figures 10.2
and 10.3.
– Pull the feeder cable and block it with
the cable clamp D
– Re-mount shield A.
N.B. The earth conductor must be left
about 3 cm longer than the others.
B
D
P
54
FEEDER CABLE SECTION
"TYPE H05RR-F"
136 PX 634
Mod.
230 V
136 PX 636
Mod.
230 V
136 PX 838
Mod.
230 V
(**) Connection with wall box connection.
(*) Diversity factor applied
A
Fig. 10.1
3 x 4 mm
3 x 4 mm
3 x 4 mm
230 V
1 2 3 4 5
L
N (L
1
PE
Earth
N
Neutral
L
Live
Red
or
Brown
L1
(Live)
Black
or
N
Blue
(L
)
2
(Neutral)
PE
Green
and
Yellow
(Earth)
2
(*) (**)
2
(*) (**)
2
(**)
)
PE
2
Fig. 10.2
Fig. 10.3
230 V ~