10. Technical data
Article no.
Air flow rate
Fan
Max. Nominal heat load
Nominal heating capacity
Temperature increase* (ΔT)
Input voltage
Current consumption
Fuel consumption max.
Air transport hose adaptor ø
Chimney connection ø
Thermostat connection
Tank capacity
Sound level (distance 1m)
Length *
Width *
Height *
Weight kg
Combustion
Power consumption
Nozzle
Adjustment of combustion air flap
Fuse
* Dimensions incl. packaging; ** Optionally available accessories necessary.
* ΔT designates the increase in temperature. The air discharge temperature is calculated using ΔT + ambient air temperature.
EN
Operating manual – IDS 900
Typ IDS 900
1.430.000.160
12.500 m³/h
Axial-Fan
221 kW (190.000 kcal)
230 V / 50 Hz
21,67 l/h
1 x 500 mm** 2 x 400 mm** 4 x 300
200 mm
75,7 dB (A)
2.235 mm
985 mm
1.500 mm
1.820 W
Delavan 2,00-80° W (U Sgal/h)
238 kW
47 °C
12 A
Series
208 l
360 kg
indirect
A = 1,5
16 A
B - 9