Wiring the Hood with an Integral Blower

Integral Blower models VTN630C and VTN1030C are
integrated into the hood at the time of installation.
For complete installation instructions see the instructions
supplied with the blower unit.
7/ 8
6
1/ 8
4
"
(175 mm)
(105 mm)
Figure 18: Integral Blower Model VTN1030C
From Control Panel
Figure 19: Wiring the Hood with an Integral Blower
1. Remove junction box channel covering the wires (see
Figure 12 on page 10).
2. Remove circular knockouts (Figure 12 on page 10).
3. Connect the blower's Molex plug connector to the
connector present inside the hood, as shown in
Figure 19.
4. Install 1" (25.4 mm) conduit connector in junction box.
5. Run black, white, and green wires (#12 AWG) in 1"
(25.4 mm) conduit from the power supply to the
junction box.
6. Connect the power supply wires to the hood wires in
the following order: black to black, white to white, and
green wire to green ground screw on chassis. Use
spring type wire nuts supplied.
1/ 4
8
" (210 mm)
7/
8
8
(225 mm)
1/ 4
2
"
(57 mm)
3/ 4
6
"
(171 mm)
"
25"
(635 mm)
From Blower
Lost or missing wire nuts should only be replaced
with spring type wire nuts rated for a minimum of
two (2) #18 gauge wires and maximum of four (4)
#14 gauge wires, UL & CSA rated to 600V and
302°F (150°C.)
7. Close the junction box cover.

Wiring the Hood with a Remote Blower

Depending on preference and ducting situation, these
blowers can be mounted on the roof or exterior wall of the
home. An exterior installation may be more appealing to
reduce noise in the kitchen.
"
For complete installation instructions see the instructions
supplied with the blower unit.
1
7/ 8
(48 mm)
(165 mm)
7/ 8
12
(327 mm)
Figure 21: Wiring the Hood with a Remote Blower
13
5/ 8
"
(346 mm)
2
1/ 8
"
(54 mm)
12
1/ 8
(308 mm)
1/ 8
2
"
(54 mm)
"
dia. 9
(251 mm)
10"
6
1/ 2
"
(254 mm)
"
19
(505 mm)
Figure 20: VTR1330E Remote Blower
"
7/ 8
"
3/ 4
20
"
(527 mm)
7/ 8
"
English 13

Publicité

Table des Matières
loading

Table des Matières