4. Disconnect battery charger from the receptacle.
CAUTION
Do not pull the plug out of the receptacle by pulling
on the cord.
Make sure to grasp the plug when removing from
receptacle to avoid damaging cord.
5. Remove the battery from the battery charger.
Supporting the battery charger with hand, pull out
the battery from the battery charger.
Regarding electric discharge in case of new
batteries, etc.
As the internal chemical substance of new batteries
and batteries that have not been used for an
extended period is not activated, the electric
discharge might be low when using them the first
and second time. This is a temporary phenomenon,
and normal time required for recharging will be
restored by recharging the batteries 2 – 3 times.
How to make the batteries perform longer
(1) Recharge the batteries before they become
completely exhausted.
When you feel that the power of the tool becomes
weaker, stop using the tool and recharge its battery.
If you continue to use the tool and exhaust the
electric current, the battery may be damaged and
its life will become shorter.
(2) Avoid recharging at high temperatures.
A rechargeable battery will be hot immediately after
use. If such a battery is recharged immediately after
use, its internal chemical substance will deteriorate,
and the battery life will be shortened. Leave the
battery and recharge it after it has cooled for a while.
CAUTION
When the battery charger has been continuosly
used, the battery charger will be heated, thus
constituting the cause of the failures. Once the
charging has been completed, give 15 minutes rest
until the next charging.
<For UC18YRSL>
If the battery is rechraged when it is warm due to
battery use or exposure to sunlight, the pilot lamp
may light in green.
The battery will not be recharged. In such a case,
let the battery cool before charging.
<For UC18YGSL>
If the battery is charged while it is heated because
it has been left for a long time in a location subject
to direct sunlight or because the battery has just
been used, the pilot lamp of the charger lights for
1 second, does not light for 0.5 seconds (off for
0.5 seconds).
The battery will not be recharged. In such a case,
let the battery cool before charging.
When the pilot lamp flikers rapidly in red (at 0.2–
second intervals), check for and take out any
foreign objects in the charger's battery installation
hole. If there are no foreign objects, it is probable
that the battery or charger is malfunctioning. Take
it to your authorized Service Center.

BEFORE USE

Check the work area to make sure that it is clear of debris
and clutter.
Clear the area of unnecessary personnel. Ensure that
lighting and ventilation is adequate.

OPERATION

1. Mounting the blade
This unit employs a detachable mechanism that
enables mounting and removal of saw blades
without the use of a wrench or other tools.
(1) Turn on and off the switching trigger several times
so that the lever can jump out of the front cover
completely. Thereafter, turn off the switch and
remove the battery. (Fig. 6)
Lever
CAUTION:
Be absolutely sure to keep the switch turned off
and the battery removed to prevent any accident.
(2) Push the lever in the direction of the arrow mark
shown in Fig. 7 marked on the lever. (Fig. 7)
Lever
(3) Insert the saw blade all the way into the small slit of
the plunger tip with the lever pushing. You can
mount this blade either in the upward or downward
direction. (Fig. 8, Fig. 9)