Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Fault
Appliance cannot be started
Insufficient water quantity
Insufficient vacuum perfor-
mance
Insufficient cleaning result
Brushes do not turn
Appliance vibrates.
Power
Nominal voltage
Average power consumption
Suction engine output
Brush engine output
Vacuuming
Cleaning power, air quantity
Cleaning power, negative pressure
Cleaning brushes
Working width
Brush diameter
Brush speed
Dimensions and weights
Theoretical surface cleaning performance
Fresh/dirt water reservoir volume
Length (without pushing handle)
Width (without vacuum bar)
Height (without pushing handle)
Weight (without tank contents)
Noise emission
Sound pressure level (EN 60704-1)
Machine vibrations
Vibration total value (ISO 5349)
Faults
Remedy
Check if the mains plug is connected.
Socket fuse rating too low, look for proper socket.
Check fresh water level, refill tank if necessary.
Clean the ball valve in the fresh water reservoir.
Check and ensure that the fresh water reservoir is seated properly on the appliance.
Filter in the fresh water reservoir is plugged, clean filter.
Check hoses for blockages; clean if required.
Empty the wastewater reservoir.
Check and ensure that the fresh water reservoir is seated properly on the wastewater
reservoir.
Check seals on the fresh water reservoir, clean if necessary.
Clean the seals between the appliance and the dirt water reservoir and check for tight-
ness, replace if required.
Clean the fluff filter.
Clean the vacuum lips on the vacuum bar, replace if required
Suction channel plugged, clean.
Check if the vacuum bar is plugged, remove plug if required
Increase brush contact pressure.
Check the brushes for wear, replace if required.
Use brush rollers suited for the type of dirt and floor covering.
Check if foreign matters block the brushes; remove foreign matter if required.
Reduce contact pressure.
Overcurrent protective switch was triggered. The overcurrent protective switch will al-
low the operation after max. one minute.
Brush rollers are deformed because they were not unloaded by tilting the slider verti-
cally when parking the appliance; replace brush rollers.

Specifications

EN
6
-
V/Hz
120 / 60
A
W
500
W
1700
gal/s (l/s)
5,3 (20)
psi (kPa)
1,45 (10)
in (mm)
15,7 (400)
in (mm)
3,8 (96)
1/min
650
ft
/h (m²/h)
4300 (400)
2
gal (l)
2,6 (10)
in (mm)
20,5 (520)
in (mm)
18,5 (470)
in (mm)
15 (380)
lb (kg)
98 (44,5)
dB(A)
m/s²
10
71
1,0
9