Technical data

The technical data of customised versions may differ from the data in these instructions.
Please observe the informations specified on the type plate.
SolarTemp
Reading range
Resolution
Accuracy
Housing
Degree of protection
Ambient temperature
Power supply
Illuminance
Measurement cycle
Digital display
Remote thermometer for explosive atmospheres:
Measurement circuit with type of protection "intrinsically safe" EEx ia IIC only for connection to re-
spective pick-ups with a maximum cable length of 10 m.
For explosive atmospheres
- by gas
- by dust
SolarTemp with transmitter (optional)
additional / Modified technical data for transmitter version:
Linearity deviation
Loop voltage
Output signal
Load
Sensor break
Short circuit
Electrical connection
Applies to explosive atmosphere version:
Signal circuit with type of protection "intrinsically safe" EEx ia IIC.
Only for connection to a certified intrinsically safe circuit. Highest value: Ui = 26.4 V.
For explosive atmospheres
- by gas
- by dust
- 16 -
see type plate
0.1 K
Class 1 acc. to DIN EN 13190
Square housing, stainless steel 1.4301, frame nickel plated
98 mm x 98 mm
IP 65
-20 °C ... +60 °C
by integrated photovoltaic cell
50 Lux
3 s
4-digit, 7-segment display, 27 mm high
Maximum surface temperature 85°C
Maximum housing temperature 80°C
< 0.1 % FS
15...26 V DC, reverse polarity protected
4...20 mA
Ra =(Ub - 15 V) / 21 mA
> 21 mA (NAMUR NE43)
< 3.6 mA (NAMUR NE43)
Connector for cable connection in accordance with EN 175301-803-A,
Cable gland for d = 6.5–13 mm,
Cable cross section up to A = 1.5 mm²
Maximum surface temperature 200°C
Maximum housing temperature 125°C
© SiKA • Ba_SolTemp_en.doc 01/2011