Troubleshooting; Front Panel Power Indicator Is Not Lit; No Sound; Protection Indicator Is Lit - Rotel RB-1092 Manuel D'utilisation

Amplificateur de puissance stéréophonique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 9
RB-1092 Stereo Power Amplifier

Troubleshooting

Most difficulties in audio systems are the result of
poor or wrong connections, or improper control
settings. If you encounter problems, isolate the
area of the difficulty, check the control settings,
determine the cause of the fault and make the
necessary changes. If you are unable to get
sound from the RB-1092, refer to the sugges-
tions for the following conditions:
Front Panel Power Indicator Is
Not Lit
No main power to the RB-1092. Check AC
power connections at the amplifier and the
AC outlet. Check the front panel power switch.
Make sure that it is set to the ON position. If
using 12V trigger power-on, make sure that
a trigger signal is present at rear panel 12V
TRIG IN jack.

No Sound

If the amp is getting AC power, but is producing
no sound, check the PROTECTION INDICATOR
on the front panel. If lit, see below. If not, check
all of your connections and control settings on
associated components. Make sure that your
input connections and speaker connections
match your system configuration.

Protection Indicator Is Lit

One or both of the front panel PROTECTION
INDICATORS will light when the RB-1092
protection circuits have shut off the amplifier.
Typically, this occurs only when the amplifier
has overheated, when there is faulty speaker
wiring, or after a period of extreme use. Turn off
the system and wait for the amp to cool. Then
push the front panel power switch in and out
to reset the protection devices. If the problem
is not corrected or reoccurs, there is a problem
with the system or the amplifier itself.
Specifications
Power Configurations
Watts/Channel
Total Harmonic Distortion (20Hz-20kHz, 8 ohms)
Continuous Rated Power
One-Half Rated Power
One Watt per Channel
Power Output (4 Ohms, 0.09% THD)
Output Peak Current
Intermodulation Distortion 60 Hz:7 kHz, 4:1
Damping Factor (8 ohms)
Amp Gain
Input Sensitivity/Impedance
Frequency Response
Signal to Noise Ratio (IHF A)
Power Requirements
USA
Europe
Power Consumption
Dimensions (W x H x D)
Panel Height (for rack mounting)
Weight (net)
All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.
8
2 x 500 Watts
500 watts, all channels driven, with 20KHz filter,
8 ohm load, 20-20 kHz, 0.03% THD
< 0.03%
< 0.03%
< 0.03%
1000 watts
40A
< 0.03%
400
27.2dB
2.2 V / 11.1 k ohms
10 - 40 KHz (±3dB)
118 dB
120 Volts, 60 Hz
230 Volts, 50 Hz
600 Watts
69 Watts - Idling
3 Watts - Standby
432 x 92 x 407 mm
17
1
/
x 3
5
/
x 16
1
/
in
8
8
8
80 mm, 3
1
/
in
8
10 kg, 22 lb.

Publicité

Table des Matières
loading

Table des Matières